Attention! 

 
General safety details 

Everybody who is involved with the installation, start-up, maintenance and operation of the Lubricus Lubrication System must 
read these instructions carefully! 

 Use in accordance with guide

 

Lubricus Lubrication System is 

only

 allowed for 

industrial use

Lubricus Lubrication System may only be put into service, if it is integrated or attached to another 
machine and will be operated together with that machine. 

Lubricus  Lubrication  System  may  only  be  used  according  to  the  technical  data  (see  chapter 

“technical data”)

 

Unauthorized 

structural changes

 at the Lubricus Lubrication System are 

not permitted

. We do 

not assume liability for damages of persons or machines which result from that. 

 

Additional directives for use in accordance with the regulations: 
 

 

Pay attention to all notes in the operator’s manual

 / user guide. 

 

Carry out all maintenance work. 

 

Follow

 all appropriate regulations for the 

work safety 

and 

accident prevention

 during life of the Lubricus Lubrication 

System. 

 

Only qualified and authorized personnel can carry out required work on the Lubricus Lubrication System. 

 

Other uses or uses beyond those described above cannot be considered to be in accordance 
with the regulations. 

Extent of warranty 

Warranties concerning operating safety, reliability and capacity, are only granted under the following conditions: 
Assembly, installation, maintenance and repair are only carried out through trained specialist. Hazardous hot or cold 
machine parts must be shielded to prevent touching.  

-The Lubricus Lubrication System must be used according to the instructions in the technical operating manual 
-The rated technical data must not be exceeded in any case. 

-Retrofitting and repair work on the Lubricus Lubrication System may only be done by the manufacturer.   

General safety information 

Basic information, which must be followed during service, operation and maintenance, are listed as follows. 

It is absolutely essential to read the operator’s manual / user guide by respective technical staff / technical operator befo

re 

installation and start up. In addition to this, it must be permanently available at the site. 

 

IMPORTANT 

Please pay attention, not only to the safety instructions under this main point, but also to those special security cautions that 

are mentioned on the other pages. 
 

 

This symbol warns of electrical voltage. 
 

 

 
 
 This symbol warns of electrical voltage. 

 

 

Attention! 

Содержание Lubricus LUB-D1

Страница 1: ...version 04 2013 User Guide Lubricus Lubrication System LUB D1 LUB D2 LUB D3 LUB D4 24 VDC...

Страница 2: ...4 General safety information 4 Transport and storage 6 Function Principle 7 Communication Interface Connector PIN assignment 7 Installation instruction Pulse signals details 8 Functional problems err...

Страница 3: ...ning Lubricus Lubrication System is designed for use in normal industrial environment indoor as well as outdoor but is not suitable for mounting on moving equipment for example trucks Only use origina...

Страница 4: ...on System Other uses or uses beyond those described above cannot be considered to be in accordance with the regulations Extent of warranty Warranties concerning operating safety reliability and capaci...

Страница 5: ...be protected from touching The protection on moving or rotating parts must not be removed In case of leakages of dangerous media proper disposal not endangering environment and people must be ensured...

Страница 6: ...oads Store the Lubricus Lubrication System in a cool and dry place to avoid corrosion of the system s individual parts Pay attention to the current safety and accident prevention instructions during t...

Страница 7: ...inued PIN 4 relays the operating condition Connector PIN assignment connection to Lubicus Type D Output signal in case of empty lubricant reservoir PIN 4 generates an alternating high and low signal s...

Страница 8: ...UB C 4 LUB C 1 1 Activate 1 1 Activate 1 1 1 2 outlets will be served alternately and dispense equal quantities from both outlets Activate 2 1 Activate 2 1 2 2 outlets will be served alternately and d...

Страница 9: ...5cm 1 5cm outlet 2 2 10 x 0 15cm 1 5cm Modell LUB D 1 1 outlet 1 1 20 x 0 15 cm 3 0 cm outlet 1 2 closed outlet 2 1 20 x 0 15 cm 3 0 cm outlet 2 2 closed Functional problems Error messages faults The...

Страница 10: ...move it 4 Remove the empty cartridge 5 Remove protection from the new cartridge 6 Lubricate O Ring of the new cartridge slightly 7 Place the cartridge on the inlet 8 Place the pump upright on flat sur...

Страница 11: ...ight without lubricant ca 1120g Integrated Control micro processor controlled Pressure monitoring integrated electronic monitoring backpressure Level monitoring integrated reedcontact Connector M12 x...

Страница 12: ...en disposing lubricant the waste disposal instructions of the lubricant manufacturer must be observed Disposal of Lubricus Lubrication System observe the regional valid laws and regulations The empty...

Отзывы: