3
PB
3. Assemble the
filter (3) on the
suction hose and
fasten in place
with a hose
clamp.
4. Screw the pump
body (1) onto
the drum or tank,
taking care to
place the pump in
a vertical position.
5. Assemble the delivery
hose onto the delivery
nozzle of the pump
body and fasten the
bent spring over the
delivery nozzle with a
clamp as described
on the “Bent Spring
Device” instruction
sheet.
6. Assemble the
dispensing nozzle
(3) onto the
opposite end of the
delivery hose and
fasten in place with
a hose clamp.
• The motor and switch are not of an anti-explosive type. Do
not use the pump in areas where there is risk of explosion.
• Do not use the pump for gasoline, inflammable liquids with
PM < 55° C, Food Liquids, Corrosive Chemical Products and
Solvents.
• Do not smoke or use open flame during refuelling.
• Avoid spilling diesel, which is harmful to the environment.
• Never operate the pump when empty.
• Do not leave the motor running under delivery in closed
condition ( i.e when the Trigger (9) is not pressed ) for
more than five minutes .
• The pump only works in a vertical position.
• The pump must only be used under the surveillance of the
operator
• Before connecting the pump to the power supply, ensure
that the voltage complies with the limitations indicated.
Power that is out of specified limits can damage the electrical
components.
Max. acceptable variation = +/- 5% of the nominal value
1. PRIMING PROCEDURE
:- Open the nozzle by pressing the
trigger (9). Start the pump by repeatedly activating the lever
(8) until the liquid starts flowing from the dispensing nozzle.
2. When fluid starts flowing out, start the motor using the
switch (10) and proceed to fuelling.
3. When finished, release the Trigger and switch off the motor.
COMMISSIONING AND USE
The operator must repeat “PRIMING PROCEDURE” under
the following situations -
• After an extended stop,
• If liquid does not flow,
• If the motor is re-started
• After a power failure.
Bent
Spring
Device
Straight end of the bent spring should be oriented
to the top of the pump and held by the clamp
7. Now connect the pump to power source .