background image

10

•  Always wear protection gear like safety goggles, gloves, apron, 

and ear plugs while operating the pump

•  Never smoke near the pump. Do not use the pump near a source 

of spark / open flames

•  DO NOT under any circumstances put you fingers inside the 

pump with the electric power connected. Serious injury can 
occur.

•  Always switch off the motor after use, so that media cannot leak 

in case any of the pump component fails

•  Before switching on the motor, check hoses for sign of wear, leak 

or loose fittings

• 

If the temperature of motor goes above 85°C, the motor stops 
working for a few minutes. It automatically starts once its 
temperature falls down to 65°C.

•  When changing the working fluid, at least 1 litre of new fluid 

should be discarded to avoid mixing of fluids

•  Pump should NOT be operated for more than 30 minutes 

continuously. Wait for 30 Minutes before restarting the pump

•  Before attempting any maintenance or repair of this product, 

disconnect power supply and then squeeze Nozzle trigger to 
release any built up pressure from hose / pump

•  Use only genuine factory parts for repair

SPECIFICATIONS

12V DC

24V DC

Flow Rate (at pump outlet)

Up to 12 GPM (46 LPM)

Motor

1/4 HP 12V DC

1/4 HP 24V DC

Amp draw from Battery

16 Amp

9 Amp

RPM

2600

Duty Cycle

30 mins. On / 30 mins Off

Internal bypass valve

Yes

Hose

4m X 3/4” ID 

- in Base Plate Style

3m X 3/4” ID 

- in Drum Mount Style

Pump Inlet

3/4” (F) 

- in Base Plate Style

    1” (F)   

- in Drum Mount Style

Pump Outlet

3/4" NPT

Battery Cable

2 metre

Safety Fuse

15 Amp

WETTED COMPONENTS

Steel, Aluminum, Zinc, Cast Iron*, Nylon, Nitrile Rubber & 
PVC Nitrile
*Only for Drum Mount version

RECOMMENDED USE

Diesel & Kerosene

DO NOT USE WITH

Fluids with a flash point below 100°F (38°C), such as 
Gasoline & Alcohol
Sparking could result in explosion causing fatal injury

Table 6

Groz Engineering Tools (P) Ltd.
Groz Net Industries

Village Kherki Daula, National Highway-8
Gurgaon-122001, Haryana, INDIA
TEL  +91.124.282.7700 / 221.4050
FAX  +91.124.2827986 / 221.4224
FAX (USA)  +1.509.271.7848
FAX (UK)     +44.870.121.1854

E-MAIL  [email protected]
URL       www.groz-tools.com

The Groz name, Groz logo and the         mark are 
trademarks of Groz Engineering Tools (P) Ltd. India

Содержание EDP/12

Страница 1: ...with 4m x ID hose that can be cut into two parts for use as a suction delivery hose Hardware supplied includes 3 hose barbs 3 4 4 hose clamps DRUM MOUNT STYLE Includes Pump with 2 Bung Elbow Fitting...

Страница 2: ...ues to rotate the vanes sweep the fluid to the opposite side of the crescent where it is squeezed through outlet port into the delivery hose 1 Pump with Battery Cable Lift Lever 2 Base Plate Kit Avail...

Страница 3: ...se Clamp 35 4 Screw the Fuel Control Nozzle 28 onto free end of Hose 42 tighten with a Hose Clamp 35 5 Remove two Allen Bolts 1 from Cover Plate 2 using Allen Key 30 Align the Nozzle Holder 39 with Co...

Страница 4: ...he hose or pump Be careful when fitting O rings and seals Replace them with new ones when they are removed from the pump Always lubricate them with oil or grease before fitting They must never be thre...

Страница 5: ...EPLACEMENT Refer to EXPLODED VIEW Page 6 6 Remove four Allen Bolts 1 using Allen Key size 4 Remove Cover Plate 2 Vanes 4 Rotor 6 Key 5 from Housing 12 7 Pull the Magnet Assembly 14 disconnect Armature...

Страница 6: ...T 13 INLET 17 22 25 Components 7 8 Only in Drum Mount Version Component 13 Only in Base Plate Version FIG 2 30 27 34 38 31 33 29 35 26 32 28 36 37 39 40 41 42 32 35 34 30 ONLY IN BASE PLATE VERSION ON...

Страница 7: ...Philipps Head Screw 3 25 Rocker Switch 1 PUMP ASSEMBLY 26 Battery Cable 1 27 Plastic Gland 1 28 Fuel Control Nozzle Manual 1 29 Allen Key Size 5 2 30 Allen Key Size 4 1 31 Allen Bolt M6 2 32 Hose Bar...

Страница 8: ...se Plate Version REPLACEMENT PARTS PROGRAM FOR ELECTRIC DIESEL PUMPS 12V DC 24V DC Table 3 KIT PART NO KIT DESCRIPTION CONSTITUENT PART NO PART DESCRIPTION SUPPLY CONDITION QTY PER KIT KIT RPR EDP Van...

Страница 9: ...mps terminals Ensure that the supply voltage is 12V or 24V as per the pump model 2 Check motor replace if it is faulty The Bypass Valve 11 is dirty sticky Inspect Spring 10 Bypass Valve 11 Clean repla...

Страница 10: ...ze Nozzle trigger to release any built up pressure from hose pump Use only genuine factory parts for repair SPECIFICATIONS 12V DC 24V DC Flow Rate at pump outlet Up to 12 GPM 46 LPM Motor 1 4 HP 12V D...

Отзывы: