background image

1

Revision date: 08.27.19

©2019 GrowSpan

All Rights Reserved. Reproduction 

is prohibited without permission.

STK#  

DIMENSIONS

113469H (B & C)  30' W x 5' H x 24' L

113470H (B & C)  30' W x 5' H x 36' L

113471H (B & C)  30' W x 5' H x 48' L

Actual building design and dimensions may differ from example shown.

GrowSpan

 Roll-Up Low Pro Tunnel

Содержание 113469H

Страница 1: ...ved Reproduction is prohibited without permission STK DIMENSIONS 113469H B C 30 W x 5 H x 24 L 113470H B C 30 W x 5 H x 36 L 113471H B C 30 W x 5 H x 48 L Actual building design and dimensions may dif...

Страница 2: ...chor assembly is an integral part of the high tunnel construction Improper anchoring may cause tunnel instability Failing to anchor tunnel properly may void manufacturer s warranty and may cause serio...

Страница 3: ...concrete continue with next procedure 12 Install tighten and secure end panels 13 Install tighten and secure main cover 14 Read care and maintenance information 15 Complete and return all warranty in...

Страница 4: ...not allow cover to remain open for extended time Periodically unroll cover for cleaning and to allow it to dry Remove debris and objects that accumulate on cover Use tools that will not damage cover w...

Страница 5: ...ort Lock FA4110 FA4115 Hook Loop Fasteners FA4110 FA4115 102857 End Clamp 102197 Aluminum U Channel Film Cover only 104642 A Angle Bracket 102198 Spring for Aluminum U Channel Film Cover only 102547 C...

Страница 6: ...of frame is measured from center to center of ground posts 2 After placing first corner stake string a line the frame width center to center of ground posts and drive second corner stake 3 String a l...

Страница 7: ...ring frame as described in the MUST READ document do not auger holes for ground posts Instead follow the steps to mark ground post locations and drive posts into the ground at those locations See info...

Страница 8: ...ts in place See diagram below All posts to be plumb before adding concrete Use mounting holes in posts and customer supplied fasteners and stakes to hold posts in place 3 Add concrete to anchor posts...

Страница 9: ...Wrap screws and slices with duct tape Gather parts Rafter pipes LPT190ES1W30 LPT190PS1W30 190S063 190S075 FA4472B Tek screws 100442 magnetic nut setter Duct tape STEP 1 Select rafter pipes to assembl...

Страница 10: ...n assistant hold until next rafter is added and connected with purlins 3 Set next rafter in place and secure using 5 16 bolts and nuts ATTENTION Only the two end rafters use 102857 end clamps as shown...

Страница 11: ...art section for additional information and pipe identification Purlin runs end to end down center at top of each rafter ATTENTION At this time do not install brackets that secure square peak purlin to...

Страница 12: ...over is shown rolled to peak Cover is installed later 2 Assemble end panel conduit using the 1 315 pipe noted above secure each pipe joint with Tek screw and tape over screw Slide conduit into pocket...

Страница 13: ...of end panel Attach each end of conduit to ground post using Tek screws and QH1330 brackets 3 Measure between end rafter ground posts to determine final conduit length Cut assembled conduit to fit if...

Страница 14: ...as needed so zippers function properly then continue 10 Drive a Tek screw through each clip and into rafter Position screws in a location that will not contact cover material Tape over screw if neede...

Страница 15: ...alternative steps for installation On the outside of frame attach first baseboard ground post using two 2 5 16 carriage bolts and nuts Countersink bolt heads if carriage bolts are not used Continue a...

Страница 16: ...ION 115287 Gather parts 115287 curtain stabilizer bars GS0049 splice plate FA4472B Tek screws 100442 magnetic nut setter 5 115287 115287 Side Views with baseboard without baseboard Tab Install bar as...

Страница 17: ...dditional information 2 Assemble 1 315 roll up conduits one for each side See side profile diagrams in Quick Start section for details and pipe identification NOTE Secure each pipe splice with a Tek s...

Страница 18: ...below for frame cover material Solid Black Silver Cover B Diagrams show attaching aluminum bar 110155 through cover and into peak purlin of frame Install Tek screws approximately 17 on center through...

Страница 19: ...ame after removing excess material Check cover length NOTE Once cover is wrapped around conduit conduit should rest on ground next to frame when length is correct See photo inset right 3 Unroll cover...

Страница 20: ...to 36 extension pipe using one 1 Tek screw 2 Slide 6 easy spin pipe 166P006 onto free end of 36 extension pipe 3 Attach universal joint to end of 36 extension pipe 4 Attach assembly to roll up cover...

Страница 21: ...sive 7 Repeat Steps 3 6 to apply hook hoop fastener in all remaining locations on frame 8 Beginning with one side roll cover down to stabilizer bar and lock cover into place 9 Verify cover is position...

Страница 22: ...12 from rafter splice Positon B Approx 36 from top center of rafter Positions C Mid point between A B GROUND LEVEL X X X X X X X Length 48 GROUND LEVEL X X X X Length 24 GROUND LEVEL X X X X X X Leng...

Страница 23: ...Repeat as cover rolls down tunnel frame End fasteners can be reached when cover is locked down Film is shown Actual cover may differ ATTENTION Never leave cover partially open Cover must be fully ope...

Страница 24: ...Guide GrowSpan Roll Up Low Pro Tunnel 30 Wide Frame Ground Level 2 Embedment Customer Supplied Baseboard Optional ATTENTION Diagram shows optional baseboard installed below stabilizer bar If baseboar...

Страница 25: ...14 2 30 0 CENTER TO CENTER OF GROUND POSTS 2 0 EMBEDMENT 2 5 1 16 9 5 16 1 4 1 16 5 7 11 16 GROUND LEVEL TO STRUCTURE PEAK GROUND LEVEL ATTENTION Diagram shows optional baseboard installed below stab...

Страница 26: ...POST 102676 RAFTER LPT190ES1W30 RAFTER LPT190ES1W30 RAFTER LPT190PS1W30 RAFTER 190S063 RAFTER 190S063 RAFTER 190S075 RAFTER 190S075 ALUMINUM BAR 110155 IF APPLICABLE PURLIN BRACKET END 102857 MID 1025...

Страница 27: ...ar If baseboard is not used install stabilizer bar at ground level 4 0 RAFTER SPACING 24 0 CENTER TO CENTER OF GROUND POSTS 2 0 EMBEDMENT GROUND LEVEL SIDEWALL PURLIN SIDEWALL PURLIN ROLLUP CONDUIT 13...

Страница 28: ...ROUND LEVEL SIDEWALL PURLIN PEAK PURLIN STABILIZER BAR 131S075 5 131P0735 1 PEAK PURLIN 102897 4 S15P048 1 STABILIZER BAR SIDEWALL PURLIN ROLLUP CONDUIT 115287 3 CUSTOMER SUPPLIED BASEBOARD OPTIONAL A...

Страница 29: ...ar If baseboard is not used install stabilizer bar at ground level 4 0 RAFTER SPACING 48 0 CENTER TO CENTER OF GROUND POSTS 2 0 EMBEDMENT GROUND LEVEL SIDEWALL PURLIN PEAK PURLIN STABILIZER BAR 131S07...

Страница 30: ...30 113469_70_71HBC Revision date 08 27 19 Connections ATTENTION Optional baseboard not shown...

Страница 31: ...X 1 TEK SCREW CROSS CONNECTOR 102857 VIEW 6 SIDEWALL PURLIN CONNECTION END RAFTER RAFTER PURLIN 2X 12 X 1 TEK SCREW CROSS CONNECTOR 102547 VIEW 7 SIDEWALL PURLIN CONNECTION MID RAFTER NOTE TEK SCREWS...

Страница 32: ...PLODED VIEW 2X 12 X 1 TEK SCREW EVERY 17 ALUMINUM BAR 110155 BLACKOUT MATERIAL PURLIN 1 5 SQ BLACKOUT MATERIAL CONNECTION PEAK IF APPLICABLE CLEAR FILM CONNECTION PEAK IF APPLICABLE NOTE BLACKOUT COVE...

Страница 33: ...ce Photo above shows frame with film cover Cross connectors secure side purlin to rafters Stabilizer bar is shown secured to outside of frame and runs near ground level the full length of the frame Th...

Отзывы: