APP Operation
The PV linkage mode require the EV charger to connect with an external current sensing
device, and choose the corresponding configuration (CT or meter type, choose the right
brand of the meter type, Acrel or Eastron).
Function of importing from the grid
Disable the function of importing power from the grid.
The EV will be charged dynamically only by surplus solar power when the surplus solar power
is greater than Min. operation power*, When surplus solar power is lower than Min.
operation power, then the EV charger will stop charging .
Enable the function of importing power from the grid set the max. importing value
The EV will be charged dynamically only by surplus solar power when the surplus solar power
is greater than *Min. operation power, when surplus solar power is lower than *Min.
operation power, the EV charger will use grid power to offset the shortage part and keep
charging at Min. operation power.
Note: *Min. operation power: 1.4kW for three-phase EV charger, and 4.1kW for three-phase
EV Charger.
Boost Function
Manual Boost Function
It is useful if users arrive home with an almost empty battery and users want to charge the
EV quickly to ensure enough energy for a short trip when the solar energy is insufficient
While users enable the manual boost function and set “start time” and “end time”, the EV
charger will charge the EV at its max. power during a set period even drawing the power
from the grid, after that, it will recover back to the normal PV linkage mode.