5.3 REFRIGERATION CONNECTIONS
Brazing
The brazing shall be carried out by qualified gas plumbers and in accordance with the current local
regulation. Any damage caused by incorrect welding procedure will invalidate any warranty.
Refrigeration Connections
NOTE: PIPEWORK SHOULD BE COMPLETED IN ACCORDANCE WITH AUSTRALIAN STANDARDS.
COMPLIANCE IS THE RESPONSIBILITY OF THE INSTALLER.
Refrigeration quality copper pipes must be used to connect the thermodynamic panel and the Little Magic
Thermodynamic Box.
This piping must be properly insulated with flexible anti-condensation insulation.
Direct contact between the refrigeration outlet and refrigeration inlet line shall be avoided to prevent
energy losses in the system.
Before brazing the piping, the system should be checked to ensure it is free of humidity and particles.
The gas piping shall be designed with as few bends as possible to minimize the load loss and it shall be
supported properly with a view not to transmit stresses or vibrations.
Please check for leaks before insulating the pipes.
Fig 8. Refrigeration connections.