MAC ADDRESS
0001CE20001
ADV-C2-MLT-00000001
ADVANCE
Load/Clear
Status
Reset
!
!
12V 5A MAX
RS-485
A B S
Optical
Tamper
Run cabling from the doors, locks, inputs and outputs.
The case includes breakouts to permit cable entry and a void
behind the case offers plenty of space for cabling.
Attach the case to the wall in the desired
location.
The optical tamper will operate as soon as the
case is closed
Connect a suitable 12V external power supply,
if required.
If using PoE there is no need to follow this step.
Connect the IP and/or RS485 cable as
required, please note for all controller
configuration IP must be connected first.
If using PoE, IP connection will apply power to
the controller.
Snap the Blade into the controller. Ensure the
Blade is inserted before any power source is
connected.
For
Door Blade
connections, see page 12
For
I/O Blade
connections, see page 16
For
OSDP
Blade connections, see page 14
Install the lithium polymer back-up battery if
required.
The battery ensures operation of equipment
during power outage. Note that data is retained
even without a battery fitted.
Once power is applied to the
controller it will be visible to the
Janus C4 Configurator application.
1
1
2
2
3
3
4
4
5
5
6
6