Fault/ cause/ remedy
Fault
Cause
Remedy
Indicator lamp in the fitting
flashes
• Battery voltage too low
- Replace battery,
see
Replacing battery
No flushing
• Water supply interrupted
- Open isolating valve
in wall connection box
• Battery voltage too low
- Replace battery,
see
Replacing battery
• Filter in solenoid valve blocked
- Clean or replace filter,
see
Cleaning or replacing filter
• Plug-in connector without contact
- Attach plug-in connector
• The detection zone of the sensor system
is set too low/too high
- Increase/reduce detection zone using
remote control
(special accessories 36 206)
• Solenoid valve defective
- Replace solenoid valve,
see
Replacing solenoid valve
• Electronics faulty
- Replace electronics,
see
Replacing the top plate
with electronics
Water flowing continuously
• Solenoid valve defective
- Replace solenoid valve,
see
Replacing solenoid valve
Undesired flushing
• The detection zone of the sensor system
is set too high
- An opposite object will be detected.
Reduce detection zone using remote
control (special accessories 36 206).
Flow volume too low
• Flow volume set too low
- Adjust flow volume,
see
Setting the flow volume
• Filter in solenoid valve blocked
- Clean or replace filter,
see
Cleaning or replacing filter
• Solenoid valve defective
- Replace solenoid valve,
see
Replacing solenoid valve
Flow volume too high
• Flow volume set too high
- Adjust flow volume,
see
Setting the flow volume
• Solenoid valve defective
- Replace solenoid valve,
see
Replacing solenoid valve
Содержание Tectron 37 750
Страница 37: ...34 UAE...
Страница 38: ...35...
Страница 39: ...36...
Страница 42: ...39 H 36 206 36 206...
Страница 66: ...63 36 206 36 206...
Страница 81: ...78 36 206 36 206...
Страница 82: ...III 17 K 17mm D D1 D1 30mm 18 K1 1 2 K 17mm 16 D D1 D1 15 14 H 13 D E 19 D E 20 D E 21 E2 E3 E4 E 22 D F E...
Страница 83: ...IV...
Страница 84: ......