2
GB
Applications
Can be used in conjunction with:
• Pressurised storage heaters
• Thermally controlled instantaneous heaters
• Hydraulically controlled instantaneous heaters
Operation with unpressurised storage heaters (displacement
water heaters) is
not
possible.
Use as:
• Bath installation
• Shower installation
Technical data
• Flow pressure
- min.
0.5 bar
- recommended
1 - 5 bar
- Operating pressure max.
10 bar
• Test pressure
16 bar
If static pressure exceeds 5 bar, a pressure reducing
valve must be fitted.
Avoid major pressure differences between hot and
cold water supply.
• Flow rate at 3 bar flow pressure:
Approx. 25 l/min
• Temperature:
Hot water inlet
max. 80 °C
Recommended (energy saving)
60 °C
• Water connection
hot - left
cold - right
Important note:
Do not install shut-off valves in the outlet pipe (mixed
water) downstream of this concealed mixers.
Note:
The GROHE Rapido E concealed universal fitting body is
intended for use as a bath or shower installation.
In the case of concealed shower mixers with bath filling and
overflow sets, observe the following:
• According to EN1717 an approved safety device is
stipulated. A special accessory can be used for this purpose
(see Replacement parts, fold-out page I, Prod. no.: 29 008).
Installation
Installation,
see fold-out page II Fig. [1].
Refer to the dimensional drawing on fold-out page I.
For different installation options, see the pre-drilled holes
in Fig. [1].
Prepare the holes for the single lever mixer and slots
for the pipe.
Align single lever mixer using fitting template and install,
see Fig. [2].
• The finished surface of the wall must lie within the area (A)
of the fitting template.
• The hot water supply must be connected on the left and the
cold water supply on the right.
Align single lever mixer,
see Fig. [1].
Place a spirit level on the cams (B) of the mounting template.
Connect the pipes,
see Fig. [2].
• When installing the shower mixer, the plug (C) provided,
see fold-out page I, must be sealed in the unused outlet (top
or bottom).
A soldered connection is not permissible,
as this could
damage the built-in sound absorber.
Open cold and hot-water supply and check fitting connections
for water-tightness.
Flush pipe thoroughly.
Fit substrate for sealant,
see Figs. [3] and [4].
1. Apply sealant or adhesive, see Fig. [3].
2. Remove (D1) centre piece of substrate (D) by cutting
through the tabs (D2).
3. Push the substrate (D) over the fitting template.
4. Apply sealant or adhesive again, see Fig. [4].
Plaster and tile the wall,
see Fig. [5].
Do
not
cut the fitting template before final installation.
Replacement parts,
see fold-out page I (* = special
accessories).