Exposed Installation

The standard position is outlet to bottom.

The Pressure Balance Valve is fixed to the 
wall via the backplate and connected to the 
supply pipes by a pair of elbows. The elbows 
are preassembled with set screws to the 
valve body. The chassis is fixed to the cover 
of the valve body by screws.

For reversed supplies installation refer to 
page 10.

1.Ensure that the projections of the supply 

pipes, (i.e. exposed beyond the wall sur-
face) have the correct length (13 - 18mm) 
and distance (150mm), see Fig. [1].

2.Place the backplate (A) with the fillet (A1) 

onto the mixer body (B). Make sure  that 
the locating pins (B1) on the valve body 
slot into the apertures on the back
plate (A2).

3.Place the valve body (B) with the elbows 

and backplate (A) to the supply pipes, see 
Fig. [2].

4.Mark the holes in the backplate for wall 

plugs, see Fig. [3].

5.Remove valve body with backplate from 

supply pipes.

6.Drill the holes (6mm) for the wall plugs (C) 

and fit them into the wall, see Fig. [4].

1

A2

B1

A

B

A1

2

B

A

3

4

C

Содержание Grohsafe 35 237

Страница 1: ...2 RUS 26 F 3 S 7 PL 11 H 15 SLO 19 LV 23 E 4 DK 8 UAE 12 P 16 HR 20 LT 24 Grohsafe Grohsafe 95 064 331 M 205474 01 06 35 237 GB 5 I 5 N 9 GR 13 TR 17 BG 21 RO 25 GB 2 NL 6 FIN 10 CZ 14 SK 18 EST 22 RU...

Страница 2: ...dy Stop Handle Screw Cap Chassis Handshower Shower Rail Flexible Hose Filter Backplate Screws Clips Screws and wallplugs Scale Ring Screws Washers Screws Nipple Table Of Contents Installation Dimensio...

Страница 3: ...II Spare Parts 3 4 Spare Parts Spare Parts...

Страница 4: ...e from this fitting No Description Cat No Pack ing unit 8 Handshower 28 422 1 9 Filter 07 002 2 10 Shower rail 28 666 1 10 1 Sliding shower holder 07 659 1 10 2 Shower rail holder 45 362 1 10 2 1 Cove...

Страница 5: ...ating valves upstream of the mixing valve for servicing purposes and in line strainers to prevent the ingress of water borne debris New Water Regulations This GROHE product is designed to comply with...

Страница 6: ...ections of the supply pipes i e exposed beyond the wall sur face have the correct length 13 18mm and distance 150mm see Fig 1 2 Place the backplate A with the fillet A1 onto the mixer body B Make sure...

Страница 7: ...he valve body B to the backplate with clips E and screws F Do not use excessive force to tighten the screws E 10 Tighten the compression nuts torque min 20 Nm see Fig 7 11 Slide the chassis G with the...

Страница 8: ...crews M1 15 Push adjustable hot water limit stop N to the intermediate handle H as de scribed in Fig 11 Please refer to chapter Maximum Hot Water Limit Setting on page 11 for limiting maximum outlet t...

Страница 9: ...e the four corner screws S1 and valve cover S 10 Pull the pressure balancing cartridge T out of the valve body Do not damage the O ring seals see Fig 14 Reverse the pressure balancing cartridge 180 by...

Страница 10: ...Fig 15 2 Detach hot water limit stop N 3 Turn the intermediate handle H counter clockwise until the outlet water reaches the desired temperature see Fig 16 4 Place the hot water limit stop N over the...

Страница 11: ...dy noting the location of H and C marking near the cartridge inlets The pressure balancing cartridge T must be replaced as a complete unit Reassemble in reverse order Ensure the two alignment pins T1...

Страница 12: ...vironment friendly cleaning liquid Grohclean is specially formulated to gently clean the surface of our fittings Problem Cause Remedy Shower control opening through hot Hot and cold water supplies hav...

Страница 13: ...14...

Страница 14: ...nctional defects for which we are responsible limitations see E F B It is our option if we correct the defects by repair or replacement C During the above guarantee period we will not charge for the c...

Отзывы: