11
Installation
Maximum Hot Water Limit Setting
On applications requiring limiting the valve
opening from full hot position, the adjustable
hot water limit stop must be reset as de-
scribed below.
1.Detach handle cap (P) loosen screw (O1)
and remove handle (O), see Fig. [15].
2.Detach hot water limit stop (N).
3.Turn the intermediate handle (H) counter-
clockwise until the outlet water reaches
the desired temperature, see Fig. [16].
4.Place the hot water limit stop (N) over the
splines on the intermediate handle with the
limit stop resting against the chassis stop
post, see Fig. [17].
5.Close the valve by turning the intermediate
handle clockwise.
6.Reinstall handle as described in Fig. [15]
in reversed direction.
15
O1
O
H
N
P
16
H
17
N