background image

15

Guarantee

Guarantee declaration

Our products correspond to the valid tech-
nical and water supply standards as well as 
the relevant approvals requirements. We 
guarantee them to be free of design and 
production faults at the time of delivery and 
that with correct use and care in accordance 
with our printed instructions they will function 
reliably.

Guarantee period 

- The guarantee is valid in private homes for 

5 years from the purchase date. Proof of 
purchase has to be provided when making 
a guarantee claim.

-  By use in commercial or institutional appli-

cations the guarantee is valid for 1 year 
after first use. An extension of the 
guarantee up to 5 years can be achieved 
by showing that the product is 
professionally maintained each year.

To make a guarantee claim, proof of pur-
chase or, the beginning of use is required. 
The guarantee period is not renewed or in-
creased through supply of spare parts or 
repair during the guarantee period. The 
guarantee period for purchased spare parts 
is the same as for original products. 

Guarantee performance

A)During the whole guarantee period we will 

correct all functional defects for which we 
are responsible (limitations see E + F).

B)It is our option if we correct the defects by 

repair or replacement.

C)During the above guarantee period we will 

not charge for the cost of parts, travel, 
working time, freight and packaging 
needed to effect the correction of defects.

D)If we are not able to correct the defect we 

are prepared to supply a replacement 
product.

E)Deliberate or careless damage is not co-

vered by this guarantee. If the installation, 
assembly or care instructions that were 
valid at the time of installation are not fol-
lowed or the product is used for a purpose 
other than that given in the written infor-
mation the guarantee declaration does not 
apply. Problems caused by dirt, lime-scale 
or aggressive cleaners are not covered by 
the guarantee.

F)The guarantee becomes void if repairs are 

not carried out competently or spare parts 
of non GROHE origin are used.

G)Replaced parts become the property of 

GROHE and are to be surrendered to our 
service personnel or sent to our registered 
offices.

Please enter date of purchase and installation here.

Our address

GROHE Limited
1, River Road 
Barking, 
Essex, IG11 OHD
GB
Tel.: 0208 / 594 72 92
Fax: 0208 / 594 88 98

 Grohe Water Technology AG & Co. KG · P.O. Box 13 61 · D-58653 Hemer/Germany

Tel. +49 (0) 23 72 / 93 - 0 · Fax: +49 (0) 23 72 / 93 13 22

Содержание Grohsafe 35 237

Страница 1: ...2 RUS 26 F 3 S 7 PL 11 H 15 SLO 19 LV 23 E 4 DK 8 UAE 12 P 16 HR 20 LT 24 Grohsafe Grohsafe 95 064 331 M 205474 01 06 35 237 GB 5 I 5 N 9 GR 13 TR 17 BG 21 RO 25 GB 2 NL 6 FIN 10 CZ 14 SK 18 EST 22 RU...

Страница 2: ...dy Stop Handle Screw Cap Chassis Handshower Shower Rail Flexible Hose Filter Backplate Screws Clips Screws and wallplugs Scale Ring Screws Washers Screws Nipple Table Of Contents Installation Dimensio...

Страница 3: ...II Spare Parts 3 4 Spare Parts Spare Parts...

Страница 4: ...e from this fitting No Description Cat No Pack ing unit 8 Handshower 28 422 1 9 Filter 07 002 2 10 Shower rail 28 666 1 10 1 Sliding shower holder 07 659 1 10 2 Shower rail holder 45 362 1 10 2 1 Cove...

Страница 5: ...ating valves upstream of the mixing valve for servicing purposes and in line strainers to prevent the ingress of water borne debris New Water Regulations This GROHE product is designed to comply with...

Страница 6: ...ections of the supply pipes i e exposed beyond the wall sur face have the correct length 13 18mm and distance 150mm see Fig 1 2 Place the backplate A with the fillet A1 onto the mixer body B Make sure...

Страница 7: ...he valve body B to the backplate with clips E and screws F Do not use excessive force to tighten the screws E 10 Tighten the compression nuts torque min 20 Nm see Fig 7 11 Slide the chassis G with the...

Страница 8: ...crews M1 15 Push adjustable hot water limit stop N to the intermediate handle H as de scribed in Fig 11 Please refer to chapter Maximum Hot Water Limit Setting on page 11 for limiting maximum outlet t...

Страница 9: ...e the four corner screws S1 and valve cover S 10 Pull the pressure balancing cartridge T out of the valve body Do not damage the O ring seals see Fig 14 Reverse the pressure balancing cartridge 180 by...

Страница 10: ...Fig 15 2 Detach hot water limit stop N 3 Turn the intermediate handle H counter clockwise until the outlet water reaches the desired temperature see Fig 16 4 Place the hot water limit stop N over the...

Страница 11: ...dy noting the location of H and C marking near the cartridge inlets The pressure balancing cartridge T must be replaced as a complete unit Reassemble in reverse order Ensure the two alignment pins T1...

Страница 12: ...vironment friendly cleaning liquid Grohclean is specially formulated to gently clean the surface of our fittings Problem Cause Remedy Shower control opening through hot Hot and cold water supplies hav...

Страница 13: ...14...

Страница 14: ...nctional defects for which we are responsible limitations see E F B It is our option if we correct the defects by repair or replacement C During the above guarantee period we will not charge for the c...

Отзывы: