Fault / Cause / Remedy
Fault
Cause
Remedy
Water not flowing
• Filter in solenoid valve blocked
• Solenoid valve defective
• Plug-in connector without contact
• Generator defective
• Storage electronic defective
• Battery (Emergency power supply) empty
- Clean filter
- Replace solenoid valve
- Check 4 plug-in connectors
- Replace generator
- Replace storage electronic
- Replace battery housing
Indicator lamp in the
sensor system flashes
• Generator defective and battery almost
empty (Fitting is supplied by emergency
power)
• Storage electronic defective and battery
almost empty (Fitting is supplied by
emergency power)
- Replace generator and battery housing
- Replace storage electronic and battery
housing
Indicator lamp in storage
electronic does not light
while the water flow
• Plug-in connector without contact
• Generator defective
- Check plug-in connection between generator
and storage electronic
- Replace generator and battery housing
Indicator lamp in storage
electronic flashes while
the water flow
• Storage electronic defective
- Replace storage electronic and battery
housing
Undesired water flow
• Sensor system detection zone set too high
for local conditions
• Automatic flushing activated
• Solenoid valve defective
- Reduce range using remote control
(special accessory, Prod. No.: 36 407)
- Wait 1 - 10 minutes or deactivate automatic
flushing, see programme table
- Replace solenoid valve
Flow rate too low
• Mousseur dirty
• Filter in solenoid valve dirty
• Filter in connection hose dirty
- Clean or replace mousseur
- Clean filter
- Clean or replace filter
Содержание EUROECO COSMOPOLITAN E + POWERBOX 36 384
Страница 2: ...I ...
Страница 3: ...II 19 017 13mm 1 2 Ø6 3a 19mm 19mm Ø6 3b 19mm 19mm 19mm 19mm 19mm 3c 19mm 4 5 6 ...
Страница 26: ...23 ...
Страница 27: ...24 ...
Страница 60: ......
Страница 61: ......
Страница 62: ...III 1 2 1 2 3 1 1 2 2 3 4 ...
Страница 63: ...IV 1 2 1 ...