Application 

Operation is possible in conjunction with:
- Pressurized storage heaters
- Thermally controlled instantaneous heaters
- Hydraulically controlled instantaneous heaters
Operation with low-pressure storage heaters (displacement 
water heaters) is 

not

 possible.

Specifications 

• Minimum flow pressure

0.4 bar

• Maximum operating pressure

10 bar

• Test pressure

16 bar

If static pressure is greater than 5 bar, fit pressure reducer.
Avoid major pressure differences between cold and hot water 
supply.
• Flow rate at 0.

bar flow pressure with flow straightener:

approx. 9 l/min

• Temperature

- Hot water inlet (maximum): 

80 

°

C

- Recommended (energy saving):

 60 

°

C

• Water connection 

cold - right

 

hot - left

Notes:

- Please follow all applicable local codes when setting the 

temperature on the hot water heater, as local municipalities 
may have codes limiting the maximum hot water heater 
setting to 50 °C.

- Major pressure differences between cold and hot water 

supply should be avoided.

- To be installed according to local codes and regulations.
- This faucet is not intended for the use with portable 

appliances.

Installation

Refer to the dimensional drawings on page 1.

Flush piping system prior and after installation of fitting
thoroughly 

(Consider EN 806)!

Mount faucet on basin,

 see figs. [1] and [2].

• Valve with a groove on the top edge of the cartridge (A) and 

in addition marked with COLD should be mounted on the 
right (cold water) side, see fig. [1].

• Valve without a groove on the top edge of the cartridge (A) 

and in addition marked with HOT should be mounted on the 
left (hot water) side.

1. Push on escutcheon (B), see fig. [1].
2. Place seal (C) on basin and insert faucet through the holes 

of the basin.

3. Push on washer (D) from below.
4. Screw on counter nut (E) and tighten with an 27mm open-

ended wrench.

5. Close the cartridges (clockwise for the hot side and counter-

clockwise for the cold side).

6. Push on lever (F).
7. Screw the brass nut (G) into the cap until tight. 

Hand tighten only!

It is recommended that the lever (N) be installed so they 
point away from the spout when in the off position.

8. Insert swivel spout (H) and secure with clip (J), see fig. [2].

Connect faucet, 

see fig. [1].

For this purpose the supply must be connected to the angle 
stops (or other supply points).
The cold water supply should be connected on the right, the 
hot water supply on the left side.

Open cold and hot water supply and check connections 
for leakage!

Maintenance

Inspect and clean all parts, replace as necessary and grease 
with special grease.

Shut off cold and hot water supply!
I. Ceramic cartridge,

 see fig. [3].

1. Unscrew brass nut (G) and pull off lever (F).
2. Unscrew cap (K).
3. Unscrew ceramic cartridge (A) using a 17mm wrench.
4. Change complete ceramic cartridge (A) or O-ring (A1).

Observe the different replacement part numbers of the 
cartridges,

 see page 2.

II. Flow straightener,

 see page 2.

Unscrew and clean flow straightener (13 929).

Replacement parts,

 see page 2 ( * = special accessories).

Care

Dear Customer,

We want to ensure that you get long-lasting satisfaction and 
pleasure from your GROHE fitting. Therefore, please read the 
following care instructions because damage to the surface and 
underlying material resulting from improper treatment is not 
covered by warranty.

Do not use any abrasive sponges or scouring agents for 
cleaning. We also advise you not to use cleaning agents 
containing solvent or acid, limescale removers, household 
vinegar and cleaning agents with acetic acid in them. They are 
aggressive to the surface - and will leave your fitting dull and 
scratched. As the formulations of commercially available 
cleaning agents frequently change, we cannot guarantee they 
will provide the gentle care our fitting deserves.

Clean the fitting with a little soap and a moist cloth only, then 
simply rinse off and wipe dry. You can avoid lime spots by 
drying the fitting each time it is used. If lime deposits do occur, 
remove them with 

GrohClean

, our environment-friendly 

cleaning liquid. 

GrohClean

 is specially formulated to clean the 

surface of our fittings gently. 

GrohClean

 is available from your 

supplier.