Service
Reset error message E9
, automatically approx. 20 minutes after
cooling down to max. 32 ° C or by interrupting the power supply
approx. 30 seconds after cooling.
• Let cool down the cooler for least 10 -15 min.
• Press and hold the
and
simultaneously until
SE
flashes in
the display.
• Release buttons
• Wait about 10 Sec.
• The remaining filter capacity will be displayed and error message
E9 is reset.
If EE flashes or the problem cannot be rectified, interrupt the power
supply to the cooler/carbonator. Note down the serial number of the
cooler/carbonator and contact Grohe Customer Service Hotline at
4008811698.
The GROHE Blue Home cooler/carbonator may only be repaired by
GROHE Service.
Environment and recycling
For reasons of hygiene, it is not possible to recycle used filter
cartridges. Used filter cartridges can be disposed of hazard-free as
residual waste.
You can purchase a refill set for the attached Co2 cylinder at our
Grohe Authorised dealers or by scanning the QR code on the
packaging
The cooler/carbonator is an electrical device, to which return and
take-back obligations apply in many countries. GROHE participates
in such take-back systems in all relevant countries.
When preparing your device for disposal, please make sure to
safely store your device and protect the refrigerant circuit from
damage. The device contains a
flammable
coolant.
Importer:
GROHE (Shanghai) Sanitary Products Co., Ltd.
Fault
Cause
Remedial action
Water not flowing
• Filter not installed correctly
• Hoses kinked
• Water supply interrupted
- Insert filter straight
(1.5- 2 turns).
- Check hoses for kinks.
- Open shut-off valves fully.
E1 in the display, no filtered
water, Blue® handle flashes red
• Safety shut-off of pump
- Disconnect voltage supply,
*
Disconnect the power supply, wait 30 seconds and
re-connect.
- Insert filter straight
(1.5 - 2 turns).
- Check hoses for kinks.
- Open shut-off valves fully.
E3 in the display, no filtered water
• No connection between fitting and
cooler/carbonator
• Cable or connector faulty
- Connect plug-in connector.
*
- Contact Grohe Service.
E5 in the display, no filtered water,
Blue® handle flashes red
• Fault function of cooler/carbonator - Disconnect voltage supply,
*
Disconnect the power supply, wait 30 seconds and re-
connect.
E7 in the display, no filtered water,
Blue® handle flashes red
• Humidity detected inside the cooler - Disconnect voltage supply,
*
wait 15 minutes and re-connect.
• If condensation, the cooler is ready for operation after
that.
• If leakage occurs, the error message occurs again and
the GROHE Service must be contacted.
E8 in the display, Blue® handle
flashes orange
• Filter capacity exceeded
- Change filter cartridge immediately, see page 9.
E9 flashes alternately with HI in the
display
• Cooler/carbonator overheated
- Close Blue
®
handle, ensure ventilation and reduce
ambient temperature to max. 32 °C.
- Let cool down the cooler for least 10 -15 min.
- Reset error message E9, see below.
EC in the display, Blue® handle
flashes white
• CO
2
bottle almost empty or not in
place
- Replace CO
2
bottle or put back in place, see page 10.
No carbon dioxide in positions
Medium and Sparkling
• CO
2
cylinder empty
- Replace CO
2
bottle, see page 10.
*If the faults E1 to E7 occur three times or more, please contact GROHE customer service.
This category of device does
not
belong in
domestic waste, but
must
be disposed of
separately in accordance with the relevant national
regulations.
21
Содержание Blue HOME 31 606
Страница 3: ...I 3 11 2 2 x 2 1 5 2 1 2...
Страница 4: ...max 60mm max 45mm 1 2 3 8 35 34 6 2 1 7 405 1 4 63 68 5 3...
Страница 5: ...I 19mm 19mm 12 19mm 11 13mm 2 1 9 2 min 11mm 3 1 10 4...
Страница 6: ...I 17 18 1 2 16 15 5 19mm 14 13...
Страница 7: ...I 22 21 1 2 3 6 h 4 5 6 1 2 20 2 min 19...
Страница 9: ...I A 2 1 B C 8...
Страница 10: ...I E8 1 2 11 2 2 x 3 UltraSafe 40 575 001 1 5 2 4 5 4 5 l 6 7 8 9...
Страница 11: ...I EC CO2 1 2 CO2 1 2 3 CO2 4 1 2 3 5 6 7 10...
Страница 12: ...I 1 2 3 4 5 40 434 Xtra Clean 40 694 6 7 11 2 2 x 1 5 2 8 11...
Страница 13: ...I 9 10 11 12 13 40 434 Xtra Clean 11 2 2 x 14 UltraSafe 40 575 001 12...
Страница 14: ...I 1 2 15 16 4 5 l 17 4L 5L 18 19 20 1 2 13...
Страница 15: ...CO2 14...
Страница 16: ...15...
Страница 26: ...25...
Страница 27: ...26...