background image

1

English

Installation

- Remove the mounting template, see fold-out page I, Fig. [1].

- Make sure the water supply is turned on at the service stop 

valves (A). Stop valves must be in fully open position (slots 
horizontal) for valve to function.

- Remove adapter (B) and stop ring (C).

- Install adapter (D), see Fig. [2].

- Install stop ring (E) supplied so that mark (E1) is at right, fit 

clip (F) and sleeve (G).

- Grease the seals for the escutcheon mounting bracket (H) 

with the special grease supplied and install escutcheon 
mounting bracket (H) with mounting set (I), see Fig. [3].

- Fit the escutcheon (J).

If thermostat is installed too deep

, the fitting depth 

can be increased by 1 1/8" (27.5mm) with extension set 
Part No. 47 820, see fold-out page II.

Adjustment

Installation of the temperature control handle and 
temperature adjustment,

 see Figs. [4] and [5].

• Before the mixer is put into service if the mixed water 

temperature measured at the point of discharge varies from 
the specified temperature set on the thermostat.

• After any maintenance operation on the thermoelement.

1. Open the shutt-off valve and check the temperature of the 

water with a thermometer, see Fig. [4].

2. Turn the adapter (D) clockwise or anticlockwise until the 

water temperature reaches 100 °F (38 °C).

3. Fit scale ring (K), see Fig. [5].

4. Install temperature control handle (L) so that the button (L1) 

is at top.

5. Screw in screw (L2) and fit cap (M).

Reversed union 

(hot on right - cold on left).

Back-to-back installation is possible by reversing the cartridge-
holder, see technical product information for the concealed 
thermostatic valve.

Temperature limitation

The safety stop limits the temperature range to 100 

°

F (38 °C).

If a higher temperature is desired, the 100 

°

F (38 °C) limit can 

be overridden by depressing the button (L1), see Fig. [5].

Prevention of frost damage

When the domestic water system is drained, thermostat 
mixers must be drained separately, since non-return valves 
are installed in the hot and cold water connections.

The complete thermostat assemblies and non-return valves 
must be unscrewed and removed.

Maintenance

Inspect and clean all parts, replace if necessary and grease 
with special valve grease.

I. Thermostatic compact cartridge

1. Turn temperature control handle (L) in such a way that the 

100° F mark is at top, see Fig. [5].

2. Remove cap (M) and pull off temperature control 

handle (L).

3. Pull off scale ring (K).

4. Detach escutcheon (J) in accordance with Fig. [6].

5. Remove mounting set (I) and escutcheon mounting 

bracket (H),see Fig. [3].

6. Close both service stop valves (A), see Fig. [1].

7. Remove sleeve (G) and adapter (D), see Fig. [2].

8. Detach clamp (F) and pull off stop ring (E).

9. Remove screws (N), screw (O) and remove unit (P), see 

fold-out page III, Fig. [7].

10. Unscrew nut (Q) with 34mm wrench, see Fig. [8].

11. If necessary, lever out thermostatic compact cartridge (R) 

via recess (R1).

12. Pull out thermostatic compact cartridge (R).

Install in reverse order.

Observe the correct installation position of the 
thermostatic compact cartridge (R),

 see detail, Fig. [8].

Readjustment is necessary after every maintenance operation 
on the thermostatic compact cartridge (see Adjustment).

II. Non-return valve

1. Proceed as for maintenance of the thermostatic compact 

cartridge, points 1 - 9.

2. Remove the four corner screws (S1) and remove the valve

cover (S) as assembled unit with the O-ring (T1),
see Fig. [9].

3. Pull the cartridge holder (T) out of the valve body noting the 

location of 

"H"

 and 

"C"

.

4. Remove the check valve inserts (U1) or (U2), see Fig. [10].

If the check valves are removed it is important to reinstall them 
with the O-ring facing away from the cartridge. If they are 
installed incorrectly no water will flow.
Reassemble in reverse order.

Ensure that the hot 

"H"

 and cold 

"C"

 markings are on the 

correct side. 

- Make sure when sliding cartridge holder (T) into the body 

that the cartridge holder fits into the positioning grooves (V) 
of the body. When correctly engaged the cartridge holder 
will not rotate, see Fig. [11]. 

- Take care not to damage inlet O-ring (W).

- If the O-ring (T1) is not on the valve cover (S) re-install and 

make sure the surface of the valve cover and the O-ring (T1) 
are both clean, see Fig. [9]. 

Seat the valve cover (S) with assembled cartridge in the 
cartridge-holder (T). Do not pinch the O-ring (T1). The 
assembly should fit together with a minimum of pressing force. 
Install the cover screws (S1). Tighten lightly in a diagonal 
pattern, then tighten firmly. 

Observe the correct mounting position!

Replacement parts

, see fold-out page II ( * = special 

accessories).

Care

For directions on the care of this fitting refer to the 
accompanying Care Instructions.

Содержание ALLURE 19 305

Страница 1: ...9 CZ 14 SLO 19 LT 24 I 5 FIN 10 H 15 HR 20 RO 25 DESIGN ENGINEERING GROHE GERMANY www grohe com 19 305 ALLURE 99 0366 031 M 232367 07 14 D 1 NL 2 PL 4 P 6 BG 7 CN 9 GB 1 S 3 UAE 4 TR 6 EST 8 UA 9 F 1...

Страница 2: ...uction l utilisateur de la robinetterie Entregue estas instrucciones al usario final de la grifer a Please pass these instructions on to the end user of the fitting 2 F D E G E1 1 A B C D 5 L K L1 M L...

Страница 3: ...II...

Страница 4: ...ge 1 Turn temperature control handle L in such a way that the 100 F mark is at top see Fig 5 2 Remove cap M and pull off temperature control handle L 3 Pull off scale ring K 4 Detach escutcheon J in a...

Страница 5: ...n e gradu e L de mani re que le rep re de 100 F soit orient vers le haut voir fig 5 2 D visser le capot M y retirer la poign e gradu e L 3 Retirer la bague gradu e K 4 Retirer la rosace J comme indiqu...

Страница 6: ...nroscar la tapa M y extraer la empu adura para regulaci n de temperatura L 3 Extraer el anillo graduado K 4 Quitar el roset n J como se indica en la fig 6 5 Desenroscar conjunto de fijaci n I y sacar...

Страница 7: ...III 7 P N O 9 S S1 T T1 8 34mm R Q R1 11 T V W 180 9 34 397 10 34 331 U1 U2...

Страница 8: ...0 info grohe co jp KZ 7 727 311 07 39 info cac grohe com LT 372 6616354 grohe grohe ee LV 372 6616354 grohe grohe ee MAL 1 800 80 6570 info singapore grohe com N 47 22 072070 grohe grohe no NL 31 79 3...

Отзывы: