Application

Thermostat mixers are designed for use with hot water 
supplied from pressurized storage heaters and offer the 
highest temperature accuracy when used in this way. Given 
sufficient output (min.18 kW or 250 kcal per min), electric or 
gas-fired instantaneous heaters are also suitable.

Thermostat mixers 

cannot

 be used in conjunction with low-

pressure storage heaters (displacement water heaters).

All thermostat mixers are adjusted at the factory at a flow 
pressure of 45 psi on both sides.

If temperature deviations should exist due to special 
installation conditions, then the thermostat is to be adjusted to 
the local conditions (see Adjustment).

Specifications

Minimum flow pressure without 
downstream resistances

7.25 psi

Minimum flow pressure with 
downstream resistances

14.5 psi

Max. operating pressure

145 psi

Recommended flow pressure

14.5 psi - 72.5 psi

Test pressure

232 psi

Flow rate:

approx. 14 L/min or 3.7 gpm/20 psi

approx. 21 L/min or 5.5 gpm/45 psi

approx. 31 L/min or 8.2 gpm/100 psi

Max. water temperature at hot water inlet 

158 °F

Temperature range adjustable on

the scale marked handle

70 - 115 °F

safety stop 

100 °F

Hot water temperature at supply connection 4 °F higher than 
mixed water temperature.

Cold water connection 

= right

Hot water connection 

= left

At a flow pressure over 72.5 psi it is recommended that a 
pressure reducing valve be fitted in the supply line.

Installation

Flush piping system prior and after installation of fitting 
thoroughly! 

Install unions and screw-mount the mixer, see fold-out page I, 
Fig. [1].

Refer to the dimensional drawing on fold-out page I.

The projection can be increased by 3/4” (20mm) with an 
extension, see Replacement Parts, fold-out page II, 
Prod. no. 07 130.

Open cold and hot-water supply and check connections 
for water-tightness.

Reversed connection

 (hot on right - cold on left).

Replace thermostatic compact cartridge, see Replacement 
parts, fold-out page II, Prod. no.: 47 175 (1/2”).

When using this thermostatic compact cartridge, the Cool 
Touch function is no longer available.

Adjusting

Temperature adjustment, 

see fold-out page I Fig. [2].

Temperature limitation

The safety stop limits the temperature range to 100 °F. 

The 100 °F limit can be overridden by pressing the button, see 
Fig. [3].

Shower mixer: 

Adjusting the economy stop, 

see fold-out page III Fig. [4].

If a higher flow rate is desired, the stop can be overridden by 
pressing the button, fold-out page III  Fig. [5].

Bath mixer:

Handle operation,

 see fold-out page III Fig. [6].

Eco function, 

by pressing the button the flow rate for the 

shower can be increased.

Prevention of frost damage

When the domestic water system is drained, thermostat 
mixers must be drained separately, since non-return valves 
are installed in the hot and cold water connections. For this 
purpose, the mixer must be removed from the wall.

Maintenance

Inspect and clean all parts, replace if necessary and lubricate 
with special valve grease.

Shut off the hot and cold water supply.

Non-return valve, 

see fold-out page III, Fig. [7].

Remove connection nipple using a 12mm allen key.

Install in reverse order.

Thermostatic compact cartridge, 

see fold-out page IV, 

Fig. [8].

Install in reverse order.

Readjustment is necessary after every maintenance operation 
on the thermostatic compact cartridge (see Adjusting).

Aquadimmer (bath mixer), 

see fold-out page IV, Fig. [9].

Ceramic headpart (shower mixer), 

see fold-out page III 

and IV, Fig. [4] and [10].

Install in reverse order.

Unscrew and clean

 mousseur (13 952) 

see fold-out page II.

Replacement parts, 

see fold-out page II ( * = special 

accessories).

Care

Instructions for care of this faucet will be found in the Limited 
Warranty supplement.

www.divapor.com

Содержание 34150

Страница 1: ...2 UA 27 F 3 DK 8 GR 13 SK 18 LV 23 RUS 28 E 4 N 9 CZ 14 SLO 19 LT 24 I 5 FIN 10 H 15 HR 20 RO 25 DESIGN ENGINEERING GROHE GERMANY www grohe com 34 150 34 159 GROHTHERM 1000 NEW 99 0269 031 ÄM 231304 01 15 English 1 Français 2 Español 3 w w w d i v a p o r c o m ...

Страница 2: ... 38 C 3 100 F 38 C S v p remettre cette instruction à l utilisateur de la robinetterie Entregue estas instrucciones al usario final de la grifería Please pass these instructions on to the end user of the fitting 34 150 34 159 w w w d i v a p o r c o m ...

Страница 3: ...II w w w d i v a p o r c o m ...

Страница 4: ...pen cold and hot water supply and check connections for water tightness Reversed connection hot on right cold on left Replace thermostatic compact cartridge see Replacement parts fold out page II Prod no 47 175 1 2 When using this thermostatic compact cartridge the Cool Touch function is no longer available Adjusting Temperature adjustment see fold out page I Fig 2 Temperature limitation The safet...

Страница 5: ...acte de thermostat voir pièces de rechange volet II réf 47 175 1 2 Lors de l insertion de la cartouche compacte de thermostat la fonction Cool Touch a été supprimée Réglage Réglage de la température voir volet I fig 2 Limitation de la température La température est limitée à 38 C par le verrouillage de sécurité Il est possible d aller au delà de la limite des 38 C et d obtenir une température plus...

Страница 6: ...cho frío al lado izquierdo Sustituir el cartucho compacto de termostato véase Piezas de recambio en la página despleglable II núm de pedido 47 175 1 2 Cuando se utiliza este termoelemento de termostato la función Cool touch ya no está disponible Ajuste Ajuste de la temperatura véase la página desplegable I fig 2 Limitación de la temperatura La gama de temperaturas está limitada a 100 ºF mediante e...

Страница 7: ...III min max 4 5 6 12mm 30mm 7 w w w d i v a p o r c o m ...

Страница 8: ...II 9 19mm 17mm 10 19 332 34mm 8 IV w w w d i v a p o r c o m ...

Страница 9: ...w w w d i v a p o r c o m ...

Страница 10: ... co jp KZ 7 727 311 07 39 info cac grohe com LT 372 6616354 grohe grohe ee LV 372 6616354 grohe grohe ee MAL 1 800 80 6570 info singapore grohe com N 47 22 072070 grohe grohe no NL 31 79 3680133 vragen nl grohe com NZ 09 373 4324 P 351 234 529620 commercial pt grohe com PL 48 22 5432640 biuro grohe com pl RI 62 21 2358 4751 info singapore grohe com RO 40 21 2125050 info ro grohe com ROK 82 2 559 0...

Отзывы: