7
OM-GSSP-BL-E BOILERLESS STEAMER
Press DELIME and follow instruction displayed on the unit (shown above) for the
delime procedure. Delime process takes approximately 60-90 minutes. Once
complete the unit will restart and go through the start up diagnostic sequence.
CUP & OVERFLOW DRAINS
1. Turn your unit off and allow it to completely drain. Units will drain automatically
when the units are powered off. This is a 5 minute process.
2. Once the reservoir has completely drained (approximately 5 minutes), stand
to the hinged side of the door and slowly open the door, allowing all of the
steam to escape from the cavity. Allow the cavity to completely cool down
and confirm that the reservoir has completely emptied before cleaning the
overflow drain.
3. Remove the steam lid (image below left) and fan cover assembly (image below
right), prior to cleaning the overflow drain.
4. Insert the cleaning brush into the cup and overflow drains located at the lower,
middle, and back right side of your steamer’s cavity (image below). As the
brush is pushed through the overflow drain, it will bend to follow the shape
of the drain as it travels the length of the overflow drain. Once you use the
cleaning brush for the first time, the wire between the handle and the bristles
will retain a curved shape after the brush is removed from the overflow drain.
The brush is designed to bend/curve in this fashion. There is no need to
straighten the wire between cleaning/usage.
5. With the cleaning brush, push and pull through the entire lengthy of the cup
and overflow drains several times. The brush should be inserted at least ten
inches (10) into the cup and overflow drains to pass through the entire length
of the drain piping. Repeat as necessary until the cup and overflow drains is
clean. Ensure that the cup and overflow drains works properly by pouring or
squirting water into the cup and overflow drains and confirming that the water
is flowing freely into the drain receptacle and not being blocked and backing
up into the steamer cavity.
If the cup and overflow drains is clogged such that the cleaning brush will
not clear the blockage or if water cannot move through the cup and overflow
drains into the drain receptacle without backing up into the steamer cavity,
then a service call needs to be made and all use of the steamer must be
discontinued until the service agent evaluates the issue and confirms that the
unit is ready for further operation.
6. Clean the steaming cavity per the cleaning instructions in your operators’
manual.
7. Re-install the steam lid and fan cover assembly.
8. Leave the door open to prolong the life of the door gasket and to allow the
cavity to air out.
9. Clean, dry and store the overflow cleaning brush after each use.
10. If a replacement brush is needed, the part number is 175977.
MAINTENANCE
The Boilerless Steamer is designed for minimum maintenance and no user
adjustments should be necessary. Certain parts may need replacement after
prolonged use. If there is a need for service, only Groen Authorized Service Agents
should perform the work.
If steam or condensate is seen leaking from around the door, take the following steps:
1. Check the door gasket. Replace it if it is cracked or split.
2. Inspect the steaming chamber drain to be sure it is not blocked.
3. Adjust the door latch pin to allow for changes that might occur as the gasket ages.
a. Loosen the lock nut at the base of the latch pin, then turn the latch pin 1/4
turn clockwise, and tighten the lock nut.
b. After adjustment, run the unit to test for further steam leakage.
c. If there is still leakage, repeat the adjustment
d. Continue adjusting the pin clockwise until the door fits tightly enough to
prevent leakage. The hinge may also be adjusted.
REPLACEMENT PARTS
To order parts, contact your Authorized Service Agent. Supply the model
designation, serial number, part description, part number, quantity, and when
applicable, voltage and phase.
CONTACT US
If you have questions pertaining to the content in this manual, contact Unified
Brands at 888-994-7636 or [email protected].