background image

OM-GSSP-BL-E BOILERLESS STEAMER

Press DELIME and follow instruction displayed on the unit (shown above) for the 
delime procedure. Delime process takes approximately 60-90 minutes. Once 
complete the unit will restart and go through the start up diagnostic sequence.

CUP & OVERFLOW DRAINS

1.  Turn your unit off and allow it to completely drain.  Units will drain automatically 

when the units are powered off. This is a 5 minute process.

2.  Once the reservoir has completely drained (approximately 5 minutes), stand 

to the hinged side of the door and slowly open the door, allowing all of the 
steam to escape from the cavity. Allow the cavity to completely cool down 
and confirm that the reservoir has completely emptied before cleaning the 
overflow drain.

3.  Remove the steam lid (image below left) and fan cover assembly (image below 

right), prior to cleaning the overflow drain.

 
4.  Insert the cleaning brush into the cup and overflow drains located at the lower, 

middle, and back right side of your steamer’s cavity (image below).  As the 
brush is pushed through the overflow drain, it will bend to follow the shape 
of the drain as it travels the length of the overflow drain.  Once you use the 
cleaning brush for the first time, the wire between the handle and the bristles 
will retain a curved shape after the brush is removed from the overflow drain.  
The brush is designed to bend/curve in this fashion.  There is no need to 
straighten the wire between cleaning/usage.  

5.  With the cleaning brush, push and pull through the entire lengthy of the cup 

and overflow drains several times.  The brush should be inserted at least ten 
inches (10) into the cup and overflow drains to pass through the entire length 
of the drain piping.  Repeat as necessary until the cup and overflow drains is 
clean.  Ensure that the cup and overflow drains works properly by pouring or 
squirting water into the cup and overflow drains and confirming that the water 
is flowing freely into the drain receptacle and not being blocked and backing 
up into the steamer cavity.

 

If the cup and overflow drains is clogged such that the cleaning brush will 
not clear the blockage or if water cannot move through the cup and overflow 
drains into the drain receptacle without backing up into the steamer cavity, 
then a service call needs to be made and all use of the steamer must be 
discontinued until the service agent evaluates the issue and confirms that the 
unit is ready for further operation.

 
6.  Clean the steaming cavity per the cleaning instructions in your operators’ 

manual.

7.  Re-install the steam lid and fan cover assembly.
8.  Leave the door open to prolong the life of the door gasket and to allow the 

cavity to air out.

9.  Clean, dry and store the overflow cleaning brush after each use.
10.  If a replacement brush is needed, the part number is 175977.

MAINTENANCE

The Boilerless Steamer is designed for minimum maintenance and no user 
adjustments should be necessary. Certain parts may need replacement after 
prolonged use. If there is a need for service, only Groen Authorized Service Agents 
should perform the work.
If steam or condensate is seen leaking from around the door, take the following steps:
1.   Check the door gasket. Replace it if it is cracked or split.
2.   Inspect the steaming chamber drain to be sure it is not blocked.
3.   Adjust the door latch pin to allow for changes that might occur as the gasket ages.

a.   Loosen the lock nut at the base of the latch pin, then turn the latch pin 1/4 

turn clockwise, and tighten the lock nut.

b.   After adjustment, run the unit to test for further steam leakage.
c.   If there is still leakage, repeat the adjustment
d.   Continue adjusting the pin clockwise until the door fits tightly enough to 

prevent leakage. The hinge may also be adjusted.

REPLACEMENT PARTS

 

To order parts, contact your Authorized Service Agent. Supply the model 
designation, serial number, part description, part number, quantity, and when 
applicable, voltage and phase.

CONTACT US

If you have questions pertaining to the content in this manual, contact Unified 
Brands at 888-994-7636 or [email protected].

Содержание SMARTSTEAM GSSP-BL-10ES

Страница 1: ...tterymarch Park Quincy Massachusetts 02169 7471 NFPA 70 National Electrical Code NSF INTERNATIONAL 789 N Dixboro Rd P O Box 130140 Ann Arbor Michigan 48105 9723 888 994 7636 fax 888 864 7636 unifiedbrands net The information in this document is Confidential and shall not be disclosed to any third party without the express written consent of Unified Brands Information contained in this document is ...

Страница 2: ...TH APPLICABLE CODES THE UNIT MUST BE INSTALLED BY A LICENSED PLUMBER WHEN INSTALLED WITHIN THE COMMONWEALTH OF MASSACHUSETTS CAUTION DO NOT INSTALL THE UNIT WITH THE REAR VENTS BLOCKED OR WITHIN 2 INCHES OF A HEAT SOURCE SUCH AS A BRAISING PAN DEEP FAT FRYER CHARBROILER OR KETTLE TO AVOID DRAINAGE PROBLEMS LEVEL THE UNIT FRONT TO BACK AND PITCH SLIGHTLY TO THE FRONT INSTALLATION Minimum Clearances...

Страница 3: ...ith the basic plumbing code of the Building Officials and Code Administrators International Inc BOCA and the Food Service Sanitation Manual of the Food and Drug Administration FDA NOTE Local code may also require check valves in the water supply line DRAIN CONNECTION WARNING DO NOT CONNECT THE DRAIN DIRECTLY TO A BUILDING DRAIN BLOCKING THE DRAIN IS HAZARDOUS CAUTION DO NOT USE PLASTIC PIPE DRAIN ...

Страница 4: ... CAN CAUSE BURNS START UP After the Boilerless Steamer has been installed test it to ensure that the unit is operating correctly 1 Remove all literature and packing materials from the interior and exterior of the unit 2 Make sure the water supply line is open 3 Turn on electrical service to the unit The steamer will not operate without electrical power Do not attempt to operate the unit during a p...

Страница 5: ... 1m will no longer be available NOTE TIMED mode can be entered before pre heating has been completed but a warning screen will appear for confirmation that the user wants to proceed to the TIMED mode before the unit is to temperature or not NOTE Time is paused when the door is open only if COMPENSATING TIMER is turned ON Go to MENUàSETTINGS MANUAL MODE Manual Pan Timers 12 00pm Steaming In Progres...

Страница 6: ...tire steamer cavity to remove food and scale particles Carefully clean probes if food residue or loose scale is present A thin layer of tightly bound scale is normal and will not affect steamer performance If scale is excessive then refer to deliming instructions below 7 Clean cup and overflow drains per instructions in Cup Overflow Drains section 8 Remove drain strainer and clean thoroughly to re...

Страница 7: ... the drain receptacle and not being blocked and backing up into the steamer cavity If the cup and overflow drains is clogged such that the cleaning brush will not clear the blockage or if water cannot move through the cup and overflow drains into the drain receptacle without backing up into the steamer cavity then a service call needs to be made and all use of the steamer must be discontinued unti...

Страница 8: ...DE ALL IMPLIED WARRANTIES INCLUDING BUT NOT LIMITED TO ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE NOR ARE THERE ANY OTHER WARRANTIES EXPRESS OR IMPLIED BY OPERATION OF LAW OR OTHERWISE In no event shall UNIFIED BRANDS be liable for damages or delay or for any consequential special or contingent damages arising out of any breach of our warranty whether or not we have know...

Страница 9: ...9 OM GSSP BL E BOILERLESS STEAMER Service Log Model No Purchased From Serial No Location Date Purchased Date Installed Purchase Order No For Service Call Date Maintenance Performed Performed By ...

Отзывы: