OM-GSSP-BL-E BOILERLESS STEAMER

USER SETTINGS

SYMBOL GUIDE

 

Temperature Ready

 This symbol is green and is found in the upper left 

corner of your screen. It is visible when the unit has reached temperature.

 

Door Open

 This symbol is orange and is found in the upper left corner of 

your screen. It is displayed when the door is open.

 

Menu

 This menu option is found in the upper right corner of your display 

and is accessible from most screens. This is how you access all settings 
and user information.

 

Back Button

 This button is displayed in the upper right corner of your 

screen and is used to return to a previous screen or menu.

 

Scroll Button 

These buttons are displayed when options can not fit on 

your screen. Press appropriate button to scroll up or scroll down to access 
further options.

 

Exit Button 

Any image with an X communicates an exit option.

 

+1m Button

 This button is found on steamer timer pages and allows you 

to quickly add 1 minutes to the steam time.

MENU OPTIONS

The items shown on the right of all the menu screens (shown with blue text) can 
be changed by tapping the blue text.  It will cycle through the options.  Only items 
with blue text or a slider button can be changed.

MM/DD/YY

Set Date

English

Language

°F

Temp 

Indication

On

3

Number

of Timers

On

Compensating

Timers

On

Timer Screen

Lock

Off

12:00pm

Settings

2 min

Door Alarm

4

Brightness

Mid

Alarm Volume

On

Delime Button

Delime Reminder

Keyboard Beep

HH:MM

Set Clock

12 hr

Time Format

Contact Us

Service

Settings

Unit Info

12:00pm

Menu

Contact Us

Service

Settings

Unit Info

12:00pm

Menu

INITIAL START-UP

WARNING:  WHEN YOU OPEN THE DOOR, STAY AWAY FROM STEAM COMING OUT OF 

THE UNIT. STEAM CAN CAUSE BURNS.

START-UP

After the Boilerless Steamer has been installed, test it to ensure that the unit is 
operating correctly. 
1.   Remove all literature and packing materials from the interior and exterior of 

the unit.

2.   Make sure the water supply line is open.
3.   Turn on electrical service to the unit. The steamer will not operate without 

electrical power. Do not attempt to operate the unit during a power failure.

 

NOTE: The door MUST be closed in order for unit to heat.

4.   There is an on/off switch in the rear of the unit.  Confirm that is it in the ON 

position.  

5.  To turn the unit on, press the power button on the front control panel. The 

power button will light up and the touch screen will display that the unit is 
going through self diagnostics.

 

NOTE: DELIME button is only displayed 
during startup if the DELIME button is 
turned to ON in settings menu.  The 
default setting for DELIME button is OFF.

12:00pm

Performing self-diagnostic

12:00pm

Performing self-diagnostic

Delime

6.   Upon completion of self diagnostics, the screen will transition to the manual 

cook screen and the unit will begin pre-heating. If exited, the screen will 
transition to the home screen where it will continue to pre-heat. 

 

Manual

Pan Timers

12:00pm

Heating

In Progress

SHUTDOWN H:MM:SS

  

Pre-heating

12:00pm

Timed

Manual

Hold

7.   On initial start up, the installer needs to record the startup date in the controls.  

Go into the MENU

à

SERVICE

à

STARTUP DATE, and enter the date.  After this 

date is set, it cannot be changed. To exit this menu, hit the back arrow until you 
return to the home screen.

SHUT-DOWN

1.  To shut down the unit, press the power button on the front control panel. The 

steam generating reservoir will then fill with cold water and drain. You will see 
a shutdown progress bar on the display.

 

Shutdown in process, 

please wait

Time for a break? 

You deserve it! 

I'll see you 

tomorrow.

+1m

Содержание SMARTSTEAM GSSP-BL-10ES

Страница 1: ...tterymarch Park Quincy Massachusetts 02169 7471 NFPA 70 National Electrical Code NSF INTERNATIONAL 789 N Dixboro Rd P O Box 130140 Ann Arbor Michigan 48105 9723 888 994 7636 fax 888 864 7636 unifiedbrands net The information in this document is Confidential and shall not be disclosed to any third party without the express written consent of Unified Brands Information contained in this document is ...

Страница 2: ...TH APPLICABLE CODES THE UNIT MUST BE INSTALLED BY A LICENSED PLUMBER WHEN INSTALLED WITHIN THE COMMONWEALTH OF MASSACHUSETTS CAUTION DO NOT INSTALL THE UNIT WITH THE REAR VENTS BLOCKED OR WITHIN 2 INCHES OF A HEAT SOURCE SUCH AS A BRAISING PAN DEEP FAT FRYER CHARBROILER OR KETTLE TO AVOID DRAINAGE PROBLEMS LEVEL THE UNIT FRONT TO BACK AND PITCH SLIGHTLY TO THE FRONT INSTALLATION Minimum Clearances...

Страница 3: ...ith the basic plumbing code of the Building Officials and Code Administrators International Inc BOCA and the Food Service Sanitation Manual of the Food and Drug Administration FDA NOTE Local code may also require check valves in the water supply line DRAIN CONNECTION WARNING DO NOT CONNECT THE DRAIN DIRECTLY TO A BUILDING DRAIN BLOCKING THE DRAIN IS HAZARDOUS CAUTION DO NOT USE PLASTIC PIPE DRAIN ...

Страница 4: ... CAN CAUSE BURNS START UP After the Boilerless Steamer has been installed test it to ensure that the unit is operating correctly 1 Remove all literature and packing materials from the interior and exterior of the unit 2 Make sure the water supply line is open 3 Turn on electrical service to the unit The steamer will not operate without electrical power Do not attempt to operate the unit during a p...

Страница 5: ... 1m will no longer be available NOTE TIMED mode can be entered before pre heating has been completed but a warning screen will appear for confirmation that the user wants to proceed to the TIMED mode before the unit is to temperature or not NOTE Time is paused when the door is open only if COMPENSATING TIMER is turned ON Go to MENUàSETTINGS MANUAL MODE Manual Pan Timers 12 00pm Steaming In Progres...

Страница 6: ...tire steamer cavity to remove food and scale particles Carefully clean probes if food residue or loose scale is present A thin layer of tightly bound scale is normal and will not affect steamer performance If scale is excessive then refer to deliming instructions below 7 Clean cup and overflow drains per instructions in Cup Overflow Drains section 8 Remove drain strainer and clean thoroughly to re...

Страница 7: ... the drain receptacle and not being blocked and backing up into the steamer cavity If the cup and overflow drains is clogged such that the cleaning brush will not clear the blockage or if water cannot move through the cup and overflow drains into the drain receptacle without backing up into the steamer cavity then a service call needs to be made and all use of the steamer must be discontinued unti...

Страница 8: ...DE ALL IMPLIED WARRANTIES INCLUDING BUT NOT LIMITED TO ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE NOR ARE THERE ANY OTHER WARRANTIES EXPRESS OR IMPLIED BY OPERATION OF LAW OR OTHERWISE In no event shall UNIFIED BRANDS be liable for damages or delay or for any consequential special or contingent damages arising out of any breach of our warranty whether or not we have know...

Страница 9: ...9 OM GSSP BL E BOILERLESS STEAMER Service Log Model No Purchased From Serial No Location Date Purchased Date Installed Purchase Order No For Service Call Date Maintenance Performed Performed By ...

Отзывы: