ASSEMBLY / DISASSEMBLY

WARNING:   AFTER SERVICING GAS PIPING ON GAS MODELS, CHECK FOR GAS LEAKS 

BEFORE PUTTING UNIT BACK IN SERVICE.

WARNING:   DISCONNECT THE STEAMER FROM ELECTRIC POWER BEFORE BEGINNING 

ANY SERVICE PROCEDURES.

GENERAL INFORMATION

This section provides common removal and installation procedures for parts. 
The following procedures are based upon having access to the steamer on all 
four sides. If the steamer is installed between other appliances and there is not 
enough room on the sides for access, the steamer must be pulled out from its 
position to gain proper access.
Care should be taken in moving the steamer so as not to stress or pull on the 
electrical, gas and water connections.

CAVITY COMPARTMENT SIDE PANELS

For part number, see section on the steamer model parts list.

REMOVAL

1.  With a Phillips screw driver remove the two 10-32 screws on the lower 

edge of the panel and one at the top edge (at the center of the top panel 
overhang). The panel is retained to the steamer by these three screws and 
three spring-like clips at the rear edge.

2.  Once the screws are removed, the panel can be pulled forward about 1 inch, 

then lowered from behind the top panel overhang.

TOP COVER

For part number, see section on the steamer model parts list.

NOTE

: Under normal conditions the top should never have to be removed. The 

most likely reason for removing it is if the panel itself has been damaged by a 
falling object.
1.  Remove right side and left side panels.
2.  At the front on each side, remove the #10-32 screw securing the top to the 

front panel (see illustration).

STEAMER DISPLAY CONTROL

REMOVAL

1.  Unplug the display control harness from I/O board.
2.  Using Phillips screw driver, carefully remove the four or five screws (number 

depends on model) holding the control display enclosure to the front panel. 
Carefully make sure harness and USB cable passes through hole in front 
panel.

3.  Using a Phillips screw driver, remove the four M3 screws and carefully 

remove board. Disconnect control harness and USB cable from board.

INSTALLATION

1.  Position the board on four studs on control enclosure.
2.  Secure the board to control enclosure with four 3M screw and tighten with 

Phillips screw driver.

3.  Connect harness and USB cable to control board. Install control enclosure 

housing while carefully inserting harness and cable through the holes in the 
front panel and securing with #10-32 screws.

4.  Connect control harness to I/O board.

I/O BOARD

REMOVAL

1.  Unplug all connectors.
2.  Using a 5/26” socket, remove fout 6/32” lock nuts and remove the board 

from four studs on the high voltage panel.

INSTALLATION

1.  Position the board on four studs on the high voltage panel.
2.  Install 6/32” lock nuts onto the studs and tighten in place using a 5/16” 

socket.

3.  Insert all jacks in the same connector locations as per removal. Press firmly 

to make sure the jack is fully seated on the board.

STEAM RESERVOIR DRAIN VALVE

When the steam reservoir drain valve is de energized or (OPEN) the silicone hose 
can freely slide through the valve housing. The steam reservoir drain valve is 
located to the right of the steamer cavity.

REMOVAL

1.  Turn off power and disconnect steamer from the branch circuit. Remove 

right side panel. Let steamer drain completely.

2.  Using spring clamp pliers, disconnect ONE END of the silicone drain hose by 

loosening the drain hose clamp from the drain fitting coming from the cavity 
drain. Remove clamp.

3.  Unplug the valve electrical wires.
4.  With a 5/16 inch nutdriver, remove the two 10-32 screws holding the drain 

valve to the bracket steamer base.

5.  Remove the two 10-32 screws and remove the valve from the bracket.
6.  Loosen the clamp and remove the other end of the silicone hose from the 

drain box. Inspect the hose for any damages or lime buildup. Clean or replace 
the hose of required, then reattach to the steam reservoir drain fitting.

INSTALLATION

 

1.  Attach new drain valve to valve bracket. Slide the silicone hose through the 

drain valve housing and install hose clamp over the exposed end of the hose. 
Check that the hose is straight and not twisted.

2.  Fit the exposed end of the silicone hose onto the elbow of the cavity drain. 

Using spring clamp pliers, position and tighten the hose clamp.

3.  Plug the electrical leads of the valve into the wiring harness. Connect 

steamer to branch circuit, and turn on power.

TESTING

 

Operate steamer and allow steam reservoir to fill. Check for leaks and observe if 
drain valve fully closes. Turn off steamer and observe that drain valve opens and 
the steam reservoir drains.
1.  Reinstall right side panel.

DOOR REMOVAL/INSTALLATION/ALIGNMENT

For part number, see section on the steamer model parts list.

REMOVAL

1.  To remove the door, turn off the steamer power and allow the steamer 

to cool. Then open the door and, while supporting the weight of the door, 
remove hinge pin or remove door-to-hinge bolts.

2.  Place the door on a flat, clean table or similar support, with gasket facing up. 

Be careful not to scratch door surface.

3.  Inspect door gasket for signs of cuts, or other defects which may impair its 

function. Replace if necessary. 

NOTE

: Gasket not covered under terms of 

warranty.

INSTALLATION

1.  To install the door, apply NEVER-SEEZ lubricant to hinge pin. Align door 

with hinge and insert hinge pin, or apply Loctite 242 to the door-to-hinge 
bolts, then install door and mounting bolts. Snug bolts only, Do 

NOT

 tighten 

mounting bolts at this time.

ALIGNMENT

1.  Place a piece of masking tape over the door latch pin (bullet) hole in the door.

Содержание GSSP-BL-10G

Страница 1: ...his document is Confidential and shall not be disclosed to any third party without the express written consent of Unified Brands Information contained in this document is known to be current and accur...

Страница 2: ...dous situation exists and could result in serious injury or death Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance When you open the st...

Страница 3: ...NY POTENTIAL USER OF THE EQUIPMENT MUST BE TRAINED IN SAFE AND CORRECT OPERATIONG PROCEDURES WARNING WHEN YOU OPEN THE DOOR STAY AWAY FROM THE STEAM COMING OUT OF THE UNIT THE STEAM CAN CAUSE BURNS WA...

Страница 4: ...een displayed no cooking mode selected the heater control cycles the heating OPERATING PROCEDURE 1 Press the ON OFF push button The screen will display a self diagnostic screen with progress bar The d...

Страница 5: ...ing operation When the unit is turned off the solenoid valve opens and drains the water from the steam reservoir When water is drained from the steam reservoir it passes through the drain box and then...

Страница 6: ...t least 4 5 W C maximum 14 W C for natural gas or 12 W C maximum 14 W C for LP gas In Canada the installation must conform to the Canadian Gas Code CAN 1 B149 Installation Codes for Gas Burning Applia...

Страница 7: ...RE CLEANING THE OUTSIDE OF THE STEAMER KEEP WATER AND CLEANING SOLUTIONS OUT OF CONTROLS AND ELEVTRICAL COMPONENTS NEVER HOSE OR STEAM CLEAN ANY PART OF THE UNIT AVOID CONTACT WITH ANY CLEANSER DELIMI...

Страница 8: ...egar Commercial vinegar 5 to 7 strength has been used successfully by a number of SmartSteam users as a descaler Follow the same instructions as when using delimer descaler CLEANING STEPS If the Delim...

Страница 9: ...9 SM GSSP BOILERLESS STEAMER GSSP BL 5E 208 240V 1 PHASE GSSP BL 5E 208 240V 3 PHASE GSSP BL 5E 480V 3 PHASE USING 277V ELEMENTS IN WYE CONFIG GSSP BL 10E 208 240V 1 PHASE GSSP BL 10E 208 240V 3 PHASE...

Страница 10: ...rm the value for 24 VAC at the secondary of the control transformer Values should be between 22 and 26 VAC and solid red LED on I O board Record value on sheet 8 11 Check Board Temp value and confirm...

Страница 11: ...ithin 10 rating on data plate 13 Low Voltage Fatal Transformer output voltage is below 19V Ensure incoming voltage supply is within 10 rating on data plate Error Error Name Trouble Condition Error Typ...

Страница 12: ...Make sure hi limit and drain thermostats are closed AMPERAGE RESISTANCE CHART Model Voltage Phase Amperage Resistance GSSP BL 5E 208 Three Phase 34 6 1 GSSP BL 5E 240 Three Phase 29 8 3 GSSP BL 5E 480...

Страница 13: ...13 SM GSSP BOILERLESS STEAMER Wiring Diagram Schematics GSSP BL 3E 5E 10E 888 994 7636...

Страница 14: ...14 SM GSSP BOILERLESS STEAMER Wiring Diagram Schematics GSSP BL 3G 5G 10G 888 994 7636...

Страница 15: ...15 SM GSSP BOILERLESS STEAMER Wiring Diagram Schematics GSSP BL I O BOARD 888 994 7636...

Страница 16: ...16 SM GSSP BOILERLESS STEAMER Wiring Diagram Schematics GSSP BL I O BOARD 888 994 7636...

Страница 17: ...17 SM GSSP BOILERLESS STEAMER Wiring Diagram Schematics GSSP BL I O BOARD 888 994 7636...

Страница 18: ...18 SM GSSP BOILERLESS STEAMER Wiring Diagram Schematics GSSP BL I O BOARD 888 994 7636...

Страница 19: ...19 SM GSSP BOILERLESS STEAMER Wiring Diagram Schematics GSSP BL I O BOARD 888 994 7636...

Страница 20: ...20 SM GSSP BOILERLESS STEAMER Wiring Diagram Schematics GSSP BL I O BOARD 888 994 7636...

Страница 21: ...21 SM GSSP BOILERLESS STEAMER Wiring Diagram Schematics GSSP BL I O BOARD 888 994 7636...

Страница 22: ...22 SM GSSP BOILERLESS STEAMER Wiring Diagram Schematics GSSP BL I O BOARD 888 994 7636...

Страница 23: ...four studs on the high voltage panel 2 Install 6 32 lock nuts onto the studs and tighten in place using a 5 16 socket 3 Insert all jacks in the same connector locations as per removal Press firmly to...

Страница 24: ...tch inside the front panel of the steamer on each side of the cavity It is pre wired in parallel so no wiring change is necessary when the door is reversed 17 Close steamer door and operate steamer If...

Страница 25: ...three exterior screws 3 Remove the side access panel by removing the two 10x32 nuts 4 Unplug the HIS and flame sensor 5 Remove the 5 14 screws on the holding plate near the ignition tube and on the b...

Страница 26: ...44110 SCREW 8 X 1 2 HEX HD SLOT MACHINE SELF 410SS 11 11 071256 NUT HEXHEAD KEPS 10 32 2 10 145088 WELDMENT LEFT COMB CHAMBER ACCESS 1 9 143986 WELDMENT FLUE EXTENSION BRACKET BOTTOM 1 8 143976 BURNER...

Страница 27: ...TEAMER Parts List GSSP BL 3G 5G 10G BASE CAVITY ASSEMBLY 178124 9 5 7 4 7 INSULATION HIDDEN 18 SECTION A A INSUALTION HIDDEN 16 15 14 13 12 13 17 8 1 10 17 A A B BOTH SIDES 2 6 11 8 3 8 17 DETAIL B SC...

Страница 28: ...T LEFT COMB CHAMBER ACCESS 1 9 145257 WELDMENT HORIZONTAL FLUE SSB 10G 1 8 145074 BURNER ASSEMBLY INFRARED 1 7 178091 PLATE READY HOLD SENSOR GSSP 1 6 069784 8 32 KEPS NUT 2 5 178089 THERMOSTAT HOLD G...

Страница 29: ...7 NT1101 NUT HEXSERRATEDZINC 1 4 20 4 8 004173 SCREW TRS HEAD 10 32 X 3 8 8 9 143870 INSULATION CAVITY BACK SSB 10 1 10 178857 INSULATION TOP SIDE GSSP 10 1 11 145624 PANEL REAR FIREWALL SSB 10 1 12...

Страница 30: ...841 SCREW 4 40 X 1 4 HEX MS 4 12 178091 PLATE READY HOLD SENSOR GSSP 1 11 147285 THERMOSTAT READY SSB 3 5 1 10 178089 THERMOSTAT HOLD GSSP 1 9 069784 8 32 KEPS NUT 2 8 147693 SHEET GRAPHITE 3 7 141538...

Страница 31: ...3 16 FA NUT0404 NUT TINNERMAN 10 11 15 142624 INSULATION BACK SSB 5 1 14 145160 PANEL BOTTOM LEFT FIREWALL SSB 5E 1 13 097015 SNAP BUSHING 1 3 8 INCH 1 12 149465 INSULATION TOP SIDE SSB 5 1 11 143655...

Страница 32: ...REW 4 40 X 1 4 HEX MS 4 12 178091 PLATE READY HOLD SENSOR GSSP 1 11 147285 THERMOSTAT READY SSB 3 5 1 10 178089 THERMOSTAT HOLD GSSP 1 9 069784 8 32 KEPS NUT 2 8 147693 SHEET GRAPHITE 3 7 141538 PANEL...

Страница 33: ...E SSB 3E G 1 13 071256 NUT HEXHEAD KEPS 10 32 4 12 145160 PANEL BOTTOM LEFT FIREWALL SSB 5E 1 11 143657 PANEL BOTTOM RIGHT FIREWALL SSB 3 5G 1 10 143889 PANEL REAR FIREWALL SSB 3G E 1 9 143893 INSULAT...

Страница 34: ...34 SM GSSP BOILERLESS STEAMER Parts List GSSP BL 10E ELECTRIC CAVITY ASSEMBLY 178201...

Страница 35: ...35 SM GSSP BOILERLESS STEAMER Parts List GSSP BL 10E BASE CAVITY ASSEMBLY 178200...

Страница 36: ...36 SM GSSP BOILERLESS STEAMER Parts List GSSP BL 3G 5G 10G ELECTRICAL ASSEMBLY 178120...

Страница 37: ...37 SM GSSP BOILERLESS STEAMER Parts List GSSP BL 3E 5E ELECTRICAL ASSEMBLY 178110...

Страница 38: ...38 SM GSSP BOILERLESS STEAMER Parts List GSSP BL 10E ELECTRICAL ASSEMBLY 178864...

Страница 39: ...39 SM GSSP BOILERLESS STEAMER Parts List GSSP BL I O BOARD ASSEMBLY 178115...

Страница 40: ...40 SM GSSP BOILERLESS STEAMER Parts List GSSP BL 3G 5G HIGH VOLTAGE ELECTRICAL PANEL 178128...

Страница 41: ...41 SM GSSP BOILERLESS STEAMER Parts List GSSP BL 10G HIGH VOLTAGE ELECTRICAL PANEL 178963...

Страница 42: ...42 SM GSSP BOILERLESS STEAMER Parts List GSSP BL 3E 5E HIGH VOLTAGE ELECTRICAL PANEL 178126...

Страница 43: ...43 SM GSSP BOILERLESS STEAMER Parts List GSSP BL 3E 5E 480V HIGH VOLTAGE ELECTRICAL PANEL 178129...

Страница 44: ...44 SM GSSP BOILERLESS STEAMER Parts List GSSP BL 10E HIGH VOLTAGE ELECTRICAL PANEL 178127...

Страница 45: ...45 SM GSSP BOILERLESS STEAMER Parts List GSSP BL 10E 480V HIGH VOLTAGE ELECTRICAL PANEL 178962...

Страница 46: ...46 SM GSSP BOILERLESS STEAMER Parts List GSSP BL CONTROL PANEL ASSEMBLY 178119...

Страница 47: ...47 SM GSSP BOILERLESS STEAMER Parts List GSSP BL PLUMBING ASSEMBLY 178123...

Страница 48: ...48 SM GSSP BOILERLESS STEAMER Parts List GSSP BL 3G 5G 10G GAS SUPPLY PIPING ASSEMBLY 178122...

Страница 49: ...lue Date fields will require selection of the month day or year field before editing Door opening Always shuts down convection fan and heating circuit Water fill and drain allowed to proceed Circulati...

Страница 50: ...and show first Delime screen Regardless of when during startup the button is pushed the unit will fill to High probe checking make break make transition If High probe is functioning a probe based del...

Страница 51: ...il cleared by pressing the Okay button at the same time the shutdown clock at the top of the screen will start flashing until it reaches 0 00 12 00pm Timed Manual Hold SHUTDOWN H MM SS 12 00pm Timed M...

Страница 52: ...will be differentiated from the main Timed Cook alarm The audible alarm will continue until silenced by tapping the flashing 0 00 Once acknowledged the timer notification will disappear If a second ti...

Страница 53: ...open then heat will turn off Heat will remain off until READY thermostat closes Heat will remain off until READY thermostat closes then heat ON OFF cycle rate will initiate If the HOLD thermostat clos...

Страница 54: ...e LONGER THAN COOK If a Pan timer is set for longer than an active cook time a pop up warning will appear when the timer is started Okay Returns to Timed Cook screen HOLD MODE TIMER SETTING Pop up occ...

Страница 55: ...tings will be retained at power off and power disconnect SERVICE Service screen to include Startup Date grayed out after setting Unit Status Diagnostics Error Log Documents Operation Error Description...

Страница 56: ...electing each individual data box Default value in the box should be MM DD YYYY Text in the boxes should be blue to indicate to the user that it can be changed DATE CONFIRMATION Accept Accepts the dat...

Страница 57: ...g V 1 1 Firmware Update Data Retrieval Documents RTD Calibration Parameters Service Shutdown Needed Shutdown Needed Okay Cancel Unit needs to shutdown prior to entering Manual Diagnostics mode Restart...

Страница 58: ...ters Code 12 00pm 0000 Enter Parameters Code 2 3 1 5 6 4 7 9 0 8 PARAMETERS CODE Parameters screen is protected by common unchangeable 4 digit password 7256 Each digit will be briefly displayed and th...

Страница 59: ...ess Connect the USB drive before starting firmware update 12 00pm Firmware Update Start Start Firmware Update Start FIRMWARE UPDATE User shall connect a USB drive which shall have the executable files...

Страница 60: ...during third fill drain cycle Delime complete screen is displayed Progress bar 25 at High probe M B M 50 after heating and end of second fill at High probe M B M 75 after drain and refill at High prob...

Страница 61: ...atus of each component Okay Button Silences and removes alarm pop up until power is cycled If error reoccurs after power cycle pop up will reoccur Buttons and actions will vary with error type 1 30 45...

Страница 62: ...fill to the High probe drain to Low probe past for XX minutes and refill to the High probe then drain cavity to empty If front ON OFF button is pressed or shutdown counter expires and High probe is fu...

Страница 63: ...sate Tstat Open High Limit Thermostat Active Board Communication xxx mA Cooling Fan xxx mA Open Water Level High Open Water Level Overflow 12 00pm xxx mA Fill Valve xxx mA Drain Valve Condensate Valve...

Страница 64: ...ware Update Data Retrieval Documents RTD Calibration Parameters Service 12 00pm Model Model Name Serial Number 638 903 518 9631 Manufacture Date 12 04 2020 Startup Date 04 20 2020 Firmware Version 1 0...

Страница 65: ...65 SM GSSP BOILERLESS STEAMER Service Log Model No Purchased From Serial No Location Date Purchased Date Installed Purchase Order No For Service Call Date Maintenance Performed Performed By...

Отзывы: