Equipment Description
The Groen DEE/4 is a floor-mounted, tilting, steam
jacketed kettle with a thermostatically controlled, self-
contained, electrically-heated steam supply and
appropriate controls, mounted on a sturdy base. The
Model DEE/4 is available in 20, 40 or 60 gallon
capacities.
The body of the DEE/4 Kettle is constructed of
stainless steel, welded into one solid piece. The kettle
is furnished with a reinforced rim and a butterfly
shaped pouring lip. It has a steam jacket rated for
working pressures up to 50 PSI. Kettle finish is 180
emery grit on the inside and bright semi-deluxe on the
outside.
The kettle can be tilted with a hand crank to pour out
its contents. Stainless steel panels enclose the
controls and the base. Four stainless steel, tubular
legs support the unit. Bullet feet on each of the legs
can be adjusted to level the kettle.
A built-in steam generator, sized for the kettle
capacity and heated by electricity, delivers steam
into the jacket. “Airless” operation of the steam jacket
permits uniform, efficient heating at temperatures as
low as 150°F and as high as 298°F. In addition to the
adjustable thermostat for operating control, the unit
has a tilt cut-off switch, low water cut-off, safety valve,
and high-limit pressure switch as safety features.
CE units have three lights on the Control Panel. The
“POWER” light comes on when the unit is turned on.
It indicates that power is being supplied to the unit.
The “HEAT” light comes on when heating elements
are heating the kettle. The “LOW WATER” light will
come on when water level in the jacket falls below
acceptable operating levels. Refer to the section on
Jacket Filling and Water Treatment (Page 12).
A single electrical connection is required for
installation. The unit may be ordered for use with 230
VAC, 1 Phase, 50 Hz, or 400 VAC, 3 Phase, 50 Hz
power.
ELECTRICAL SUPPLY CONNECTION REQUIREMENTS
Unit
DEE/20
DEE/40
DEE/60
230 Volt - 1 Phase
57 Amperes
96 Amperes
96 Amperes
400 Volt - 3 Phase
57 Amperes
96 Amperes
96 Amperes
a.Connect the appropriate wiring as described in the wiring diagram located on the inside of the control console.
A copy is also provided at the rear of this manual.
b.Equipotential terminal - In accordance with national regulations the unit has been fitted with an equipotential
terminal.