OM-BPM/BPP-G 5
Optional equipment available with these models are:
1. Fill faucet with swing spout. (Left or right mounted) - specify single or double
pantry
2. Fill faucet with 48” or 60” spray hose assembly (left or right mounted) - specify
single or double pantry
3. Caster mounting kit
4. Flanged Feet
5. 2” Tangent draw-off (Factory-installed must be indicated on initial order)
6. Steamer Insert set
7. Steamer Pan Carrier
8. Quick gas disconnect with restraining cable
9. Pouring Lip Strainer
10. Strainer for 2” TDO valve
PERFORMANCE DATA
Equipment Description
Model
Firing Rate
BPM-15G, -15GC, -15GA
65,000 BTU/hr
BPM-15GS
BPM-30G, -30GC, -30GA
104,000 BTU/hr
BPM-30GS
BPP-30G, -30GC, -30GA
BPM-40G, -40GC, -40GA
144,000 BTU/hr
BPM-40GS
BPP-40G, -40GC, -40GA
Optional Tangent Draw-off
Содержание BPM-15G
Страница 27: ...OM BPM BPP G 27 Schematics Electronic Ignition System Manual Tilt 120 230VAC For Classic Control GC Models...
Страница 28: ...28 OM BPM BPP G Schematics Electronic Ignition System Power Tilt 120 230VAC For Classic Control GC Models...
Страница 29: ...OM BPM BPP G 29 Schematics Electronic Ignition System Manual Tilt 120 230VAC For Advanced Control GA Models...
Страница 30: ...30 OM BPM BPP G Schematics Electronic Ignition System Power Tilt 120 230VAC For Advanced Control GA Models...
Страница 31: ...OM BPM BPP G 31 Diagrams Schematics Standing Pilot Ignition System...
Страница 33: ......
Страница 34: ......
Страница 35: ......