OM-BPM-15/30/40E(C,A) (CE) INTERNATIONAL

cleaner to remove any mineral deposits or film left by hard water or foods. 
Follow the supplier’s directions very carefully, and rinse the unit off thoroughly, 
as soon as cleaning is finished.

15.  If especially difficult cleaning problems persist, contact your cleaning product 

supplier for help. The supplier has a trained technical staff with laboratory 
facilities to serve you.

MAINTENANCE

WARNING:  ELECTRIC POWER ALWAYS SHOULD BE SHUT OFF BEFORE WORK IS DONE 

ON INTERNAL COMPONENTS.

WARNING:  DISCONNECT ELECTRICAL POWER FROM THE UNIT BEFORE ATTEMPTING 

TO GREASE THE TRUNNION BEARINGS.

Your braising pan is designed to require minimum maintenance, but certain parts 
may need replacement after prolonged use. After installation, no user adjustment 
should be necessary. If a service need arises, only authorized personnel should 
perform the work.
Service personnel should check the unit at least once a year. This periodic 
maintenance should include inspecting electrical wires and connections, cleaning 
the inside of the control console, and possible adjustment of the pilot light. (Units 
with standing pilot ignition only) At least twice a year, grease the two trunnion 
bearings and worm gear.
We recommend the use of number two grade LGI lithium grease. Add grease 
through the zerk fittings on the gear hosing until grease flows out of the bearings 
around trunnion shaft. Also, add grease in the gear to cover arc that is in contact 
with the worm gear. Clean up excess grease.
A Service Log is provided with the warranty information at the back of this manual. 
Each time service is performed on your equipment, enter the date on which 
the work was done, what was done, and who did it. Keep the manual with the 
equipment for quick and easy reference.

REPLACEMENT PARTS

 

To order parts, contact your Authorized Service Agent. Supply the model 
designation, serial number, part description, part number, quantity, and when 
applicable, voltage and phase.

CONTACT US

If you have questions pertaining to the content in this manual, contact Unified 
Brands at 888-994-7636.

TROUBLESHOOTING

This unit is designed to operate smoothly and efficiently if properly maintained. 
However, the following is a list of checks to make in the event of a problem. 
Wiring diagrams are found at the end of this manual. When in doubt, turn unit 
off and call for service at 888-994-7636. If an item on the check list is marked 
with (X), it means that the work should be done by a Authorized Service Agent.

WARNING:  ELECTRICAL POWER MUST BE SHUT OFF BEFORE WORK IS DONE ON INTERNAL 

COMPONENTS.  USE OF ANY REPLACEMENT PARTS OTHER THAN THOSE 

SUPPLIED BY THE MANUFACTURER OR THEIR AUTHORIZED DISTRIBUTOR 

CAN CAUSE INJURY TO THE OPERATOR AND DAMAGE TO THE EQUIPMENT 

AND WILL VOID ALL WARRANTIES. SERVICE PERFORMED BY OTHER THAN 

FACTORY-AUTHORIZED PERSONNEL WILL VOID ALL WARRANTIES.

SYMPTOM

WHO

WHAT TO CHECK  (X indicates work that should only be 

performed by a qualified service representative)

Display not lit
(Advanced only)

User

a.   That power supply is on.

Authorized 

Service Rep 

Only

b.   Fuses, accessible by removing caps on the side of the 

control box.

c.   For loose or broken wires or damaged RTD probe. X
d.   Temperature controller functioning, by listening for a click 

when the switch opens or closes and verifying LEDs on 
back of board. X

e.   Contactor functioning. X

PROB in display
(Advanced only)

Authorized 

Service Rep 

Only

a.    For loose or broken wires or damaged/failed RTD probe. X
b.   PCB board malfunction/failure

HI in display
(Advanced only)

Authorized 

Service Rep 

Only

a.    For loose or broken wires or damaged/failed RTD probe. X
b.   PCB board malfunction/failure

Pan will not heat, 
but
indicator light 
comes on

Authorized 

Service Rep 

Only

a.   Heating elements for short circuit. X

Pan will not heat, 
and
indicator light 
will not
light (STD and 
Classic)

User

a.   That power supply is on.

Authorized 

Service Rep 

Only

b.   Fuses, accessible by removing caps on the side of the 

control box.

c.   For loose or broken wires or damaged RTD probe. X
d.   Temperature controller functioning, by listening for a click 

when the switch opens or closes and verifying LEDs on 
back of Classic board. X

e.   Contactor functioning. X

Pan continues 
to heat
after it reaches 
desired
temperature

User

a.   Temperature controller dial setting. Turn down if too high.

Authorized 

Service Rep 

Only

b.   Temperature controller functioning. X
c.   Temperature Controller calibration and offsets. X
d.   Contactor, to determine if it is de-energized. X

Pan does not 
reach
desired 
temperature

User

a.   Temperature Controller dial setting. Turn up if too low.

Authorized 

Service Rep 

Only

b.   Heating elements for ground short or open (burned out) 

element. X

c.   Temperature controller functioning, by listening for a click 

when the switch opens or closes. X

d.   Temperature Controller calibration and offsets. X
e.   Contactor functioning. X

Rapid clicking 
noise
(chattering)

User

a.   For low voltage.

Authorized 

Service Rep 

Only

b.   Contactor for dirt or corrosion on the contacts. X

Uneven cooking 
due
to “hot spots”

User

a.   That the pan body is level.

Uneven cooking 
due
to “cold spots”

Authorized 

Service Rep 

Only

a.   For open (burned out) heating element. X

Pan is hard to tilt
(Manual Tilt 
Models)

Authorized 

Service Rep 

Only

a.   Gears for foreign materials, lubrication and alignment. X

Содержание BPM-15EC/EA

Страница 1: ...r Depth BPM 15EC EA 18 1 8 460mm 28 1 4 718mm 8 203mm Manual BPM 30EC EA 26 1 4 667mm 28 1 4 718mm 10 254mm Manual BPM 40EC EA 35 3 4 908mm 28 1 4 718mm 10 254mm Manual Options accessories available w...

Страница 2: ...rent shipping damage or an incorrect shipment to the delivery agent When installation is to begin get someone to assist in removing the crate Lift it straight up and away from the unit Write down the...

Страница 3: ...KW 230 KW 240V NO NEUTRAL KW 480V NEUTRAL Amps Wire AWG Amps Wire AWG Amps Wire AWG BPM 15EC EA 7 0 30 6 8 7 6 18 10 7 0 9 12 BPM 30EC EA 10 6 46 6 11 5 28 8 10 6 15 4 12 BPM 40EC EA 14 1 61 1 4 15 3...

Страница 4: ...d display 5 HIGH TEMP and LOW TEMP presets cannot be used to change the setpoint once a TIMER has started h READY alarm The control will sound 3 beeps when the unit has reached within 20 F 7 C of set...

Страница 5: ...UTION NEVER LEAVE A CHLORINE SANITIZER IN CONTACT WITH STAINLESS STEEL SURFACES FOR LONGER THAN 30 MINUTES LONGER CONTACT CAN CAUSE CORROSION CAUTION KEEP CAUSTIC COMPOUNDS SUCH AS FRYER BOILOUT CLEAN...

Страница 6: ...EFOREWORKISDONEONINTERNAL COMPONENTS USE OF ANY REPLACEMENT PARTS OTHER THAN THOSE SUPPLIED BY THE MANUFACTURER OR THEIR AUTHORIZED DISTRIBUTOR CAN CAUSE INJURY TO THE OPERATOR AND DAMAGE TO THE EQUIP...

Страница 7: ...6521 4 BULLET FOOT W O FOOT ADAPTER 146628 5 FRICTION RING 146520 Parts List COVER COUNTERBALANCE ASSEMBLIES CALL FACTORY FOR REPLACEMENT PARTS 888 994 7636 Key Qty Description Part 1 1 COVER COUNTERB...

Страница 8: ...8 OM BPM 15 30 40E C A CE INTERNATIONAL Parts List CALL FACTORY FOR REPLACEMENT PARTS 888 994 7636...

Страница 9: ...H LIMIT THERMOSTAT 142755 15 ELEMENT 240V 146185 16 COVER ELEMENT HOUSING 15 GAL 162575 16 COVER ELEMENT HOUSING 30 GAL 146186 16 COVER ELEMENT HOUSING 40 GAL 144343 17 RIGHT SIDE COVER HIDDEN 175146...

Страница 10: ...24 2 1 SHAFT HANDWHEEL 144834 3 1 GEAR WORM 128001 4 1 GEAR SECTOR 009829 5 1 KEY GIB 012031 6 1 HANDWHEEL 139152 7 2 PIN ROLL 012614 8 2 SCREW SET SOCKET 012060 9 2 BEARING ROLLER 002790 10 2 BEARING...

Страница 11: ...11 OM BPM 15 30 40E C A CE INTERNATIONAL Wiring Diagram CALL FACTORY FOR REPLACEMENT PARTS 888 994 7636...

Страница 12: ...12 OM BPM 15 30 40E C A CE INTERNATIONAL Service Log Model No Purchased From Serial No Location Date Purchased Date Installed Purchase Order No For Service Call Date Maintenance Performed Performed By...

Отзывы: