OM-HY-3E(CE)
6
2.
Water Supply
Water connection is accomplished as explained in OM-HY-3E. The CE model water input connection has
an adapter to accept 3/4" British Standard Pipe Thread (BSPT).
3.
Drain Kit
The CE Drain Kit includes a 21½" hose, but is otherwise identical to the standard HY-3E drain kit. It is
recommended that there be at least a one inch free air gap between the end of the unit drain and the
building drain. The free air gap should be as close as possible to the unit drain. There should be no
elbows or restrictions between the unit drain and the one inch free air gap. Consult local plumbing codes
for proper installation. Install the drain line with a constant downward pitch.
CAUTION
DO NOT USE PLASTIC PIPE. DRAIN MUST BE
RATED FOR BOILING WATER.
WARNING!
DO NOT BLOCK THE DRAIN.
IMPORTANT: Do not allow any water traps in the line.
A trap can cause pressure to build up inside the cavity
during steaming, which will make the door gasket leak.