Model T32957 (Mfd. Since 09/21)
-29-
5. Adjust blade guard until entire length is same
distance from table, then tighten hex bolt.
Figure 41. Using feeler gauge to check blade
guard clearance.
Hold-Down Finger
Feeler Gauge
3. Repeat Step 2 on left end of blade guard.
— If both hold-down fingers
are
same dis-
tance from table, no adjustment is required.
— If hold-down fingers
are not
same distance
from table, proceed to
Step 4.
4. Loosen blade guard hex bolt on side of blade
guard that needs adjustment (see
Figure 42).
Figure 42. Location of blade guard hex bolts.
Adjusting Blade Guard Parallel With
Table
1. Use foot pedal to lower and hold blade guard
in lowest position.
2. Insert largest feeler gauge that will fit between
hold-down finger and table on right end of
blade guard (see
Figure 41).
Squaring
Front Scales
For the front scales to work properly, these scales
must be square to the blades.
Tools Needed
Qty
Machinist's Square ............................................ 1
Wrench or Socket 13mm ................................... 1
To square front scales:
1. Use foot pedal to lower and hold blade guard
in lowest position.
2. Place machinist's square against blade guard
and front scale.
— If scale
is
square to blade guard, no
adjustment is necessary.
— If scale
is not
square to blade guard, pro-
ceed to
Step 3.
3. Loosen (2) hex bolts for front scale that
needs adjustment (see
Figure 39).
x 2
Figure 43. Location of front scale hex bolts.
4. Place one side of machinist's square against
blade guard and adjust front scale against
other side of square.
5. Tighten hex bolts from Step 3 to secure
position.