Model T27338 (Mfd. Since 01/15)

-7

-

Compressed Air 

System

The Model T27338 is designed to be oper-
ated at 70-115 PSI using clean, dry, regu-
lated,  compressed  air. 

DO NOT exceed 

the 115 PSI maximum operating pres-
sure for your model.
 Before using, regu-
late the air pressure on your air compres-
sor to 70 psi.

An  in-line  filter/lubricator/regulator  unit, 
depicted in 

Figure 3, can be installed and 

should be located as close to the nailer as 
possible.

The  filter/lubricator/regulator  unit  will 
protect  your  tool  from  damaging  water 
build-up, allow you to adjust and maintain 
constant  air  pressure  to  your  tool,  and 
save  you  the  inconvenience  of  having  to 
manually  lubricate  your  tool  every  time 
you use it. 

Check the current Grizzly catalog for avail-
ability  of  this  unit.  If  you  plan  on  install-
ing  a  filter/lubricator/regulator  unit  in  your 
compressed air system, always follow the 
connection  instructions  that  come  with 
the unit.

Quick 
Connector

Quick 
Coupler

Air Hose

Quick 
Coupler

Quick 
Connector

Lubricator

Filter

Regulator

Air 

Compressor 

Your

Tool

Figure 3. Typical filter/lubricator/regulator installation order.

Exceeding maximum permissible 
operating pressure may cause nailer 
to explode, blowing metal fragments 
in all directions. To protect yourself 
and bystanders from serious personal 
injury, DO NOT allow your air com-
pressor to exceed the recommend-
ed pressure when connected to this 
nailer! 

Содержание T27338

Страница 1: ...INC WARNING NO PORTION OF THIS MANUAL MAY BE REPRODUCED IN ANY SHAPE OR FORM WITHOUT THE WRITTEN APPROVAL OF GRIZZLY INDUSTRIAL INC BL18231 PRINTED IN CHINA MODEL T27338 3 IN 1 FLOORING NAILER OWNER S...

Страница 2: ...g grinding tool integrity and the usage of personal protective equipment The manufacturer will not be held liable for injury or property damage from negligence improper training machine modifications...

Страница 3: ...do a job for which it was not designed DO NOT USE UNDER INFLUENCE OF DRUGS OR ALCOHOL For Your Own Safety Read Instruction Manual Before Operating This Equipment The purpose of safety symbols is to a...

Страница 4: ...TS Regularly inspect tool for any con dition that may affect safe operation Immediately repair or replace damaged or mis adjusted parts before operating tool DISCONNECT TOOLS before servic ing changin...

Страница 5: ...s NAILING Avoid driving one nail staple on top of another The nail staple may deflect and cause injury AIR SOURCE Disconnect air source before installing nails staples clearing jam moving to another w...

Страница 6: ...pecifica tions drawings and photographs of the tool we used when writing this manual However sometimes we still make an occasional mistake Also owing to our policy of continuous improvement your tool...

Страница 7: ...ire manual BEFORE using tool Become familiar with the names and locations of the controls and features shown below to better understand the instructions in this manual Handle Handle Grip Air Inlet Qui...

Страница 8: ...from around your tool and inspect it If you discover the tool is dam aged please immediately call Customer Service at 570 546 9663 for advice Save the containers and all packing mate rials for possibl...

Страница 9: ...ol and save you the inconvenience of having to manually lubricate your tool every time you use it Check the current Grizzly catalog for avail ability of this unit If you plan on install ing a filter l...

Страница 10: ...2 to install remaining L bolt The handle should appear like the one in Figure 6 when installed Figure 4 Handle placed against flooring nailer Handle 2 Slide an L bolt into mounting hole and slot in h...

Страница 11: ...pty and con tains no nails staples 3 Place flooring nailer on ground with nailer guide plate facing down then connect air hose The nailer should not fire If it does not fire proceed to Step 4 If naile...

Страница 12: ...puncture injuries to improperly placed hands or body parts Always position hands and body away from fastener trajectory and deflection paths Loading Nailer The Model T27338 shoots both nails and stap...

Страница 13: ...ty Hex Wrench 4mm 1 To change guide plate 1 DISCONNECT NAILER FROM AIR SOURCE 2 Pull magazine pusher back see Figure 10 secure it with lock button remove any nails staples from maga zine then unlock p...

Страница 14: ...rrect guide plate for size of flooring material refer to Changing Guide Plate on Page 11 2 Install nails staples in magazine refer to Loading Nailer on Page 10 3 Place flooring nailer on ground with n...

Страница 15: ...Tongue Side View Wood Subfloor Figure 13 Correct setup for operating nailer 6 Using rubber end of included hammer strike head cap with light medium force to shoot nail staple into wood DO NOT use mult...

Страница 16: ...1 If the nailer does not fire nails staples when you strike the head cap it can indi cate the nailer has jammed A jammed nail must be cleared before using the nailer again To clear jammed nail from d...

Страница 17: ...lasses 2 0 H7196 Bifocal Safety Glasses 2 5 Figure 18 Assorted safety glasses Installing unapproved accessories may cause nailer to malfunction resulting in serious personal injury or tool damage To r...

Страница 18: ...uilt for tough use the large cast aluminum body provides plenty of power for the hardest woods Features include a 360 exhaust port comfort grip rubber handle eco nomical air consumption with low noise...

Страница 19: ...s warning may lead to serious personal injury or even death Place two to three drops of pneumatic tool oil in the nailer air inlet as shown in Figure 25 before every use and after every 2 hours of con...

Страница 20: ...kits part PT27338061 are cheap insurance against wasted down time and lost profits in the event that the piston assembly or O rings become worn out Air leaking from vents under the head cap can indica...

Страница 21: ...g and split ring from top of piston assembly see Figure 30 Figure 30 Split ring and snap ring location Split Ring 7 Unscrew 3 cap screws and remove plunger see Figure 29 Figure 29 Plunger location Plu...

Страница 22: ...Dirt and oil buildup on driver 4 Exhaust port is blocked 5 Worn or damaged O rings 1 Check for blockage increase air pressure 2 Lubricate nailer Page 17 3 Disassemble clean driver 4 Clean exhaust port...

Страница 23: ...30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 31 46 47 48 49 50 51 52 53 54 56 53 52 55 56 57 58 59 60 68 67 76 16 15 SECTION 8 PARTS Main We do our best to stock replacement parts when possible but...

Страница 24: ...COVER GASKET 54 PT27338054 TORSION SPRING 1 5 X 12 X 30 18 PT27338018 NAILER BODY 55 PT27338055 E CLIP 3MM 19 PT27338019 HANDLE GASKET 56 PT27338056 MAGAZINE PIN 20 PT27338020 HANDLE 57 PT27338057 MA...

Страница 25: ...rs ____2 8 Years ____8 20 Years ____20 Years 6 How many of your machines or tools are Grizzly ____0 2 ____3 5 ____6 9 ____10 7 Do you think your machine represents a good value ____Yes ____No 8 Would...

Страница 26: ...P O BOX 2069 BELLINGHAM WA 98227 2069 TAPE ALONG EDGES PLEASE DO NOT STAPLE Name________________________________ Street________________________________ City______________State______Zip_______ Send a...

Страница 27: ...event be liable for death injuries to persons or property or for incidental contingent special or consequential damages arising from the use of our products To take advantage of this warranty contact...

Страница 28: ......

Отзывы: