-24-
Model T1242 (Mfd. Since 04/18)
Review the troubleshooting procedures in this section if a problem develops with your machine. If you need
replacement parts or additional help with a procedure, call our Technical Support.
Note: Please gather the
serial number and manufacture date of your machine before calling.
SECTION 7: SERVICE
Troubleshooting
Motor & Electrical
Symptom
Possible Cause
Possible Solution
Ram will not
move.
1. Pump not on.
2. Pressure set too low.
3. Fluid level too low.
4. Obstruction in hydraulic line.
5. Motor at fault.
6. Motor coupling has failed.
7. Pump has seized.
8. Pressure valve at fault.
9. Hydraulic ram has failed.
1. Ensure START button has been pressed and WORK
LAMP light is on.
2. Adjust pressure valve to appropriate PSI for operation
(
Page 21).
3. Check and fill tank to proper level.
4. Check hydraulic lines for obstructions.
5. Test/repair/replace.
6. Test/repair/replace.
7. Test/repair/replace.
8. Test/repair/replace.
9. Test/repair/replace.
Symptom
Possible Cause
Possible Solution
Machine does
not start, or
power supply
breaker
immediately
trips after
startup.
1. Emergency Stop button engaged/not reset.
2. Master power switch in "0" position.
3. Electrical cabinet open/safety switch at fault.
4. Incorrect power supply voltage or circuit size.
5. Power supply circuit breaker tripped or fuse
blown.
6. Start capacitor at fault.
7. Thermal overload relay has tripped.
8. Motor at fault.
1. Rotate button head to reset.
2. Turn master power switch to "1" position.
3. Close/lock electrical cabinet door.
4. Ensure correct power supply voltage and circuit size.
5. Ensure circuit is sized correctly and free of shorts,
reset circuit breaker or replace fuse.
6. Test/replace.
7. Reset; contact tech support if relay frequently trips.
8. Test/repair/replace.
Motor stalls
after running.
1. Magnetic switch contactor at fault (not
energized/has poor contacts).
2. Run capacitor at fault.
3. Motor bearings at fault.
4. Motor at fault.
1. Test all legs for power/replace.
2. Test/replace.
3. Test/replace bearings.
4. Test/repair/replace.
Machine has
vibration or
noisy operation.
1. Machine incorrectly mounted to floor.
2. Motor or component loose.
3. Motor fan rubbing on fan cover.
4. Motor at fault.
1. Adjust feet, shim, or tighten mounting hardware.
2. Inspect/replace damaged bolts/nuts, and retighten with
thread-locking fluid.
3. Fix/replace fan cover; replace loose/damaged fan.
4. Test/repair/replace.
Operations & Hydraulic System