Model T1242 (Mfd. Since 04/18)
-17-
4. Turn master power switch to "I" position (see
Figure 12). Power lamp will illuminate when
machine is receiving power.
6. Press START button to turn motor ON.
WORK LAMP light will illuminate when motor
is running. Verify motor starts up and runs
smoothly without any problems or noises.
7. Press EMERGENCY STOP button to turn
machine
OFF.
8. WITHOUT resetting EMERGENCY STOP
Button, start machine by pressing the START
button.
— If machine does not start, EMERGENCY
STOP Button is working correctly. Test
Run is complete.
— If machine does start, immediately
turn it
OFF and disconnect power. The
EMERGENCY STOP safety feature is
NOT working properly. This safety feature
must work properly before proceeding with
regular operations.
Figure 13. Resetting the EMERGENCY STOP
Button.
5. Twist EMERGENCY STOP Button clockwise
until it springs out (see
Figure 13).
Hydraulic System
Priming
Figure 12. Control panel components.
POWER LAMP
WORK LAMP
STOP
Button
START
Button
Master Power Switch
EMERGENCY
STOP Button
To prime the hydraulic system:
1. Turn machine ON.
2. Fully extend, then retract ram using ram con-
trol lever (see
Figure 14).
3. Repeat Step 2.
4. DISCONNECT MACHINE FROM POWER!
5. Check hydraulic tank fluid level.
—If fluid level is still at fill mark continue to
next step.
—If fluid level is below fill mark add hydraulic
fluid (see
Page 16).
6. Repeat Step 2.
Figure 14. Location of ram control lever and
sight glass.
A
B
Fill Cap
Tank
Sight Glass
Fill Mark
Sight Glass
Ram Control Lever
Содержание T1242