Model T10824 (Mfd. Since 07/14)
-25-
SECTION 7: SERVICE
Troubleshooting
Symptom
Possible Cause
Possible Solution
Saw does not start. 1. Power supply switched OFF, breaker
tripped, fuse blown, or power supply is at
fault.
2. Motor overloaded.
3. Motor brushes at fault.
4. ON/OFF switch at fault.
5. Motor at fault.
1. Ensure power supply is on/has correct voltage.
2. Allow the motor to cool down completely and retry.
3. Remove/replace brushes (Page 24).
4. Replace switch.*
5. Test/repair/replace.*
Saw stalls or is
underpowered.
1. Tool is undersized for task.
2. Motor brushes at fault.
3. Motor bearings at fault.
4. Motor overheated.
5. Motor at fault.
1. Use correct blade/reduce feed rate or depth of cut.
2. Remove/replace brushes (Page 24).
3. Test/repair/replace.*
4. Clean motor, let cool, and reduce workload.
5. Test/repair/replace.*
Saw has vibration or
noisy operation.
1. Damaged windings or faulty motor.
2. Blade at fault.
3. Workpiece loose.
1. Test/repair/replace.*
2. Replace warped/bent blade; resharpen dull blade.
3. Ensure workpiece is properly supported/clamped.
Cuts are rough or
wavy; workpiece
rips or splinters.
1. Saw blade is dull.
2. Incorrect blade for workpiece.
3. Excessive force when cutting.
4. Improper blade depth.
1. Resharpen or replace the dull blade.
2. Replace with proper saw blade.
3. Decrease pressure when cutting and allow saw to
move through workpiece at a slower rate.
4. Slightly increase/decrease depth of cut.
Blade is burning
workpiece.
1. Saw blade is dull.
2. Blade installed backward.
3. Incorrect blade for workpiece.
1. Resharpen or replace the dull blade.
2. Remove/re-install blade correctly (Pages 17-18).
3. Replace with proper blade.
* Solution should only be carried out by or under the supervision of qualified service personnel.