Model T32335 (Mfd. Since 11/20)
-31-
Adjusting Cut-In/
Cut-Out Settings
The pressure switch ensures the compressor will
turn
ON when the tank pressure drops to approxi-
mately 95 PSI (the cut-in pressure), and will turn
OFF when the tank pressure reaches 115 PSI (the
cut-out pressure). Should the pressure switch fail
to turn
OFF the machine, the safety relief valve
will open shortly after the pressure exceeds 115
PSI and prevent over-pressurization.
Cut-in and cut-out settings have been
factory set at proper PSI range. Only adjust
pressure switch settings if compressor
is cutting-in or cutting-out at incorrect
pressures. Tank could burst if filled with
more pressure than it is designed for.
Eye injury hazard! Always
wear safety glasses when
handling pressurized air
system.
Tools Needed
Qty
Phillips Head Screwdriver #2 ............................ 1
Flat Head Screwdriver
1
⁄
4
" .................................. 1
Adjusting Cut-In/Cut-Out Settings
If the minimum and maximum tank pressure set-
tings both have to be raised or lowered at the
same time, then follow these steps.
To adjust cut-in/cut-out settings:
1. Operate compressor and record cut-in and
cut-out pressures.
2. DISCONNECT MACHINE FROM POWER!
Figure 33. Location of pressure switch cover
Phillips head screw.
Pressure
Switch
Cover
5. Adjust screw shown in Figure 34 to change
minimum and maximum tank pressure
settings.
Figure 34. Location of cut-in/cut-out adjustment
screw.
Cut-In/
Cut-Out
Adjustment
Screw
Releasing air through drain valve can
be extremely loud. Protect hearing with
ANSI-approved hearing protection while
performing following step.
3. Use safety relief valve to reduce tank pres-
sure to less than 10 PSI.
4. Remove Phillips head screw shown in
Figure 33 to remove pressure switch cover.