Troubleshooting
Motor & Electrical
Symptom
Possible Cause
Possible Solution
Machine does not
start, or power
supply fuse/breaker
trips immediately
after startup.
1. Emergency stop button depressed/at fault.
2. Incorrect power supply voltage or circuit
size.
3. Power supply circuit breaker tripped or fuse
blown.
4. Motor wires connected incorrectly.
5. Start capacitor at fault.
6. Wiring broken, disconnected or corroded.
7. ON/OFF switch at fault.
8. Motor at fault.
1. Lift switch cover. Press ON button.
2. Ensure correct power supply voltage (
Page 10) and
circuit size.
3. Ensure circuit is sized correctly and free of shorts.
Reset breaker or replace fuse.
4. Correct motor wiring connections.
5. Test/replace if at fault.
6. Fix broken, disconnected, or corroded connections.
7. Test/replace ON/OFF switch.
8. Test/repair/replace.
Machine stalls or is
underpowered.
1. Excessive feed pressure applied.
2. Machine undersized for task.
3. Motor overheated.
4. Motor bearings at fault.
5. Motor at fault.
1. Reduce feed pressure.
2. Reduce workpiece pressure.
3. Clean motor, let cool, and reduce workload.
4. Test/repair/replace.
5. Test/repair/replace.
Machine has
vibration or
noisy operation.
1. Grinding belt not tracking correctly on
wheels.
2. Motor or component loose.
3. Stand not stable or incorrectly secured to
floor.
4. Motor fan rubbing on fan cover.
5. Motor bearings at fault.
1. Ensure belt is tracking correctly (
Page 21).
2. Replace damaged or missing bolts/nuts or tighten if
loose.
3. Tighten mounting hardware (
Page 17); shim
machine to ensure no wobbles.
4. Fix/replace fan cover; replace loose/damaged fan.
5. Test/repair/replace.