Model G0836 (Mfd. Since 09/17)
-41-
Symptom
Possible Cause
Possible Solution
Power feed does
not move table or is
slipping.
1. Power feed not plugged in.
2. Table locked.
3. Leadscrew selector knob not engaged.
4. Power feed FAULT light illuminated.
5. Direction switch not engaged.
6. Limit switches contact table travel sensor.
7. Gears not meshing or teeth missing.
8. Motor shaft and gear shaft not engaged.
1. Plug in power feed (
Page 19).
2. Unlock table locks (
Page 26).
3. Engage leadscrew selector knob (
Page 27).
4. Turn speed control dial
OFF to clear fault or
obstruction (
Page 27).
5. Select direction to start power feed motor
(
Page 27).
6. Adjust limit switch positions (
Page 26).
7. Check gears and adjust/replace.
8. Replace clutch.
Operates at high
speed only or is
inconsistent.
1. Wiring harness unplugged from circuit
board.
2. Speed control dial/potentiometer at fault.
1. Reconnect wiring harness.
2. Test/repair/replace.
Power Feed
Symptom
Possible Cause
Possible Solution
X/Y/Z-Axis DRO or
spindle depth DRO
do not give reading.
1. Spindle depth DRO battery is dead.
2. Shorted/disconnected wiring/plugs.
1. Replace battery (
Page 38).
2. Inspect sensors, plugs, and wiring connections.
Replace/repair as necessary.
X/Y/Z-Axis DRO
reading is incorrect.
2. Initial reading is incorrect.
3. Sensor has gone bad.
1. Spacing between sensor and scale is
incorrect.
2. Zero/reset DRO at beginning point.
3. Test/replace sensor as necessary.
1. Adjust spacing between sensor and scale.
Digital Readout Units (DRO)