-16-
Model G0764Z (Mfd. Since 10/15)
Connection Type
A permanently connected (hardwired) power sup-
ply is typically installed with wires running through
mounted and secured conduit. A disconnecting
means, such as a locking switch (see following
figure), must be provided to allow the machine
to be disconnected (isolated) from the power
supply when required. This installation must be
performed by an electrician in accordance with all
applicable electrical codes and ordinances.
Extension Cords
Since this machine must be permanently con-
nected to the power supply, an extension cord
cannot be used.
Serious injury could occur if you connect
machine to power before completing setup
process. DO NOT connect to power until
instructed later in this manual.
Grounding Instructions
In the event of a malfunction or breakdown,
grounding provides a path of least resistance
for electrical current to reduce the risk of electric
shock. A permanently connected machine must
be connected to a grounded metal permanent wir-
ing system; or to a system having an equipment-
grounding conductor. All grounds must be verified
and rated for the electrical requirements of the
machine. Improper grounding can increase the
risk of electric shock!
The Model G0764Z can be converted for 440V
operation. This conversion job consists of: 1)
Disconnecting the saw from the power source, 2)
moving the fuse to the 440V holder, 3) replacing
the overload relays, and 4) rewiring the main and
scoring blade motors for 440V operation. Refer to
Page 85 for a detailed 440V wiring diagram
All wiring changes must be inspected by a quali-
fied electrician or service personnel before the
saw is connected to the power source. If, at any
time during this procedure you need help, call
Grizzly Tech Support at (570) 546-9663.
Contact the Grizzly Order Desk at (800) 523-4777
to purchase the 440V Conversion Kit, Part No.
P0764Z1814.
To convert G0764Z for 440V operation:
1. DISCONNECT MACHINE FROM POWER!
2. Using a 4mm hex wrench, remove electri-
cal panel cover (see
Figure 7) from back of
frame.
440V Conversion
Figure 7. Electrical panel cover location.
Electrical Panel
Cover
Figure 6. Typical setup of a permanently
connected machine.
Power
Source
Locking
Disconnect Switch
Machine
Ground
Ground
Conduit
Conduit