-5-
110V Operation
SECTION 2: CIRCUIT REQUIREMENTS
The Model G0516 Lathe/Mill is wired for 110V
single-phase operation. The largest motor, the
3
⁄
4
HP lathe motor, will safely draw 9 amps at 110V.
A 10-amp fuse or circuit breaker should be used
when connecting this combination lathe/mill to
power. Circuit breakers rated any higher are not
adequate to protect the circuit. Always check to
see if the wires in the circuit are capable of han-
dling an 9 amp load. If you are unsure, consult a
qualified electrician.
If you operate this lathe/mill on any circuit that is
already close to its capacity, it might blow a fuse
or trip a circuit breaker. However, if an unusual
load does not exist and a power failure still
occurs, contact a qualified electrician or our ser-
vice department.
The Model G0516 is equipped with its own fuses
to prevent overload damage.
When replacing
these fuses please replace with the following:
Lathe ..................................................25A Fuse
Mill/Drill ................................................5A Fuse
NOTICE
The Model G0516 cannot be rewired for
220V operation! Attempting to do this will
void the warranty and will ruin the machine.
If you find it necessary to use an extension cord
with the Model G0516, make sure the cord is
rated Hard Service (grade S) or better. Refer to
the chart in the standard safety instructions to
determine the minimum gauge for the extension
cord. The extension cord must also contain a
ground wire and plug pin. Always repair or
replace extension cords when they become worn
or damaged.