background image

15

5.0 USE OF THE LANTERN
5.1 DMX function

To access the unit through a DMX controller KOLORADO

®

MK2 1800 must be set to MASTER

OFF. Push SELECT; when 

1.ON

is displayed push (+) or (-) to obtain 

1.OF

. Now press ENTER.

The unit is set to 

MASTER OFF

.

Note: when the KOLORADO

®

 MK2 1800 unit leaves the factory it is set to MASTER ON and

works in AUTOMATIC MODE (See AUTOMATIC MODE section).

Every single KOLORADO

®

MK2 1800 unit must have

its own display correctly set. 
Please set the display of each unit as per diagram 1 
when more units are accessed through a DMX
controller.KOLORADO

®

MK2 1800 uses 2 or 5 chan-

nels according to thechosen options.

The connection of the XLR 3 poles must be as follows:
pin 1---> function GND (SHIELD)
pin 2---> function SIGNAL -
pin 3---> function
Pls. ensure that the cables are properly connected. 
Use shielded cable.
In oreder to protect the PCB housing from water pene-
tration, it is strictly recommended to position the DMX connecting plugs as illustrated below (see
pictures 2 and 3).

5.2 Channels Indicatoion

DMX Addressing 5 Channels 2 Channels
Projector 1

0  0  1

0  0  1

Projector 2

0  0  6

0  0  3

Projector 3

0  1  1

0  0  5

Projector 4

0  1  6

0  0  7

Projector 5

0  2  1

0  0  9

Projector 6

0  2  6

0  1  1

Projector 7

0  3  1

0  1  3

Projector 8

0  3  6

0  1  5

Projector 9

0  4  1

0  1  7

Projector 10

0  4  6

0  1  9

(diag.1)

pict.1

pict.2

pict.3

Содержание Kolorado MK2 1800

Страница 1: ...Foglio di Istruzioni Owner s Manual KOLORADO MK2 1800 GR 0414 MHN SA 1800 W FI 0414 Rev 3 30 07 2001...

Страница 2: ...Indicazione dei canali 7 6 0 FUNZIONAMENTO IN AUTOMATICO 8 6 1 Master Slave 9 7 0 MANUTENZIONE 9 8 0 INFORMAZIONI TECNICHE 10 9 0 PARTI DI RICAMBIO 10 INDEX INDEX Page 1 0 PACKING 11 2 0 SAFETY 11 3...

Страница 3: ...utilizzo della catena di sicurezza da fis sare al proiettore ed alla struttura di sospensione dello stesso per evitare la caduta accidentale del proiettore nel caso poco probabile che il punto di fis...

Страница 4: ...era circolazione dell aria intorno al proiettore e contenerne il riscaldamento 3 3 Installazione con ballast separato E possibile per praticit separare il ballast dal proiettore Per eseguire questa op...

Страница 5: ...ionata nell alloggiamento pi vicino al vetro mentre il filtro di espansione va sistemato nello spazio centrale tra il paraluce e la griglia 3 6 Collegamento elrttrico 1 Cablate il cavo di alimentazion...

Страница 6: ...l accensione della lampada e il dimmer su un indirizzo personalizzato Per selezionarlo premere Select dopo avere impostato su ON l opzione 4 il display mostra l indirizzo corrente del proiettore per...

Страница 7: ...essere settato come da tab 1 tenendo presente che ogni KOLORADO MK2 1800 occupa da 2 a 5 canali a seconda delle opzioni scelte La connessione delle prese XLR 3 poli dovr avvenire come di seguito desc...

Страница 8: ...pulsante SELECT il display mostrer SP 1 Agite sui tasti e per regolare la velocit La durata dei tempi descrit ta in tab 2 E possibile regolare la durata di una scena colori premendo il pulsante SELEC...

Страница 9: ...tilissimo strato di polvere pu ridurre in modo sostanziale la resa luminosa ed alterare la compattezza del fascio sostituite specchi e i dicroici se hanno subito danni visibili quali tagli crepe e pro...

Страница 10: ...ingombro proiettore paraluce a 4 alette L668 xP798 xH633 mm Peso proiettore 31 18 5 Ballast Kg Materiale della carcassa Alluminio Tensione nominale 230 V Frequenza nominale 50 60 Hz Corrente nominale...

Страница 11: ...about 20 minutes Caution it is strongly recommended that a safety chain or wire is attached to this projector and secured to the main mounting framework to arrest the fall of the unit in the unlikely...

Страница 12: ...ct A Minimum distance from flammable objects must be 0 5m so as to make air circulation easy 3 3 Separate ballast set up The unit is fitted with a separate ballast facility and the connecting cable is...

Страница 13: ...w you previously removed The protection grid pict 3 is positioned in the slot close to the glass while the eventual expansion filter has to be placed in the middle position between the barndoor set an...

Страница 14: ...X controller DMX 4 Dimmer shutter lamp On Off Independent setting To enter this option push SELECT after you have set option 4 to ON the display shows the current projector addressing to view the dimm...

Страница 15: ...RADO MK2 1800 uses 2 or 5 chan nels according to thechosen options The connection of the XLR 3 poles must be as follows pin 1 function GND SHIELD pin 2 function SIGNAL pin 3 function SIGNAL Pls ensure...

Страница 16: ...ne and positioning length are described in picture 2 Colour scene length can be customised by pushing SELECT and the display will show PA 0 Act on or to set the colour scene length Pre set colour scen...

Страница 17: ...NTENANCE All lanterns require regular maintenance to ensure maximum performance and light output Please follow these instructions clean lenses mirrors and dichroics regularly as even a thin layer of d...

Страница 18: ...4 leaf barndoor L668 xP798 xH633 mm Weight 31 18 5 Ballast Kg Body Aluminiumand galvanised steel body Operating Voltage 230 V Operating Frequence 50 60 Hz Operating Amperage 8 5 A Power absorbed 2000...

Страница 19: ...19...

Страница 20: ...LENGE Professional Lighting Manufacturer Via Bulgaria 16 46042 CASTEL GOFFREDO MN Telefono 0376 779483 Fax 0376 779682 0376 779552 http www griven com e mail griven griven com http www griven it e mai...

Отзывы: