5.0 MAINTENANCE
This unit is certified to an IP65 protection against all kinds of weather conditions and therefore it
does not require a regular maintenance.
To obtain the maximum light output and a durable life for the unit please follow instructions
below:
- clean lenses, objective and additional dichroic filter as even a thin layer of dust can reduce the
light output and scatter the beam;
- replace lenses and additional dichroic filter if they are visibly damaged;
- replace the lamp in case it is damaged or deformed;
- carefully check the electrical connections, particularly the earth connection;
- replace lenses, or any other component should they be visibly damaged.
6.0 TECHNICAL INFORMATION
7.0 SPARE PARTS
All components for GOBOCLIP MK3 150 W units are available on request.
The exploded diagram, the eletric wiring scheme, the electronic layout and the promotional bro-
chure are available on request.
Griven S.r.l. shall be under no liability for any loss or demage in transit. Claims must be adressed
directly to the forwarder.
Griven S.r.l. will accept claims for broken or missing goods only within seven days of receipt of
the goods.
Returns of equipment will not be accepted without prior authorization granted by Griven S.r.l. and
if not duly accompained by relevant shipping documents.
The guarantee excludes all consumables.
GRIVEN products are built and assembled in compliance with CE standards and regulations.
16
!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!"#$#C&'(!M*+!C,M-S/01!2345
Size
L305 x P440 x H480
mm
Weight
9,5
Kg
Body
Aluminium
Operating Voltage
230V/250V
V
Operating Frequence
50/60
Hz
Operating Amperage
0,8
A
Power Absorbed
160
VA
Suggested lamp
CDM-SA/T 150W
Base
G 12
Optic System
Coated elliptical reflector
Electtronic system fuse
5x20 250V 6,3A
Max working temperature
90
°C
Max ambient temperature
35
°C
Содержание GOBOCLIP MK3