English
25
1. Red
RED
2. Green
GRE
3. Blue
BLU
4. White
UHT
Once positioned onto the desired colour, press “ENTER” to confirm. By the keys “UP”and “DOWN” select “ON” or
“OFF”. It is possible to activate or disactivate the colours. Press ENTER to confirm.
Now the unit is in FIXED COLOURS mode and the diplay will keep reading “COL”.
To exit from the FIXED COLOURS mode, press the “MENU” button, select “ACT” and press “ENTER” to confirm.
Select “OFF” to deactivate the FIXED COLOURS mode. Press ENTER to confirm.
8.2 DW MASTER configuration
The FIXED COLOURS mode ONLY works when 3 channels DMX mode is set.
To activate the FIXED COLOUR mode, press the “MENU” button up to visualize “ADR”. Through the “UP” and
“DOWN” keys select “COL”. Press “ENTER” to confirm.
Through the “UP” and “DOWN” keys select “ACT”. Through the “UP” and “DOWN” keys select “ON” or “OFF” to
activate or deactivate the FIXED COLOUR mode. Press “ENTER” to confirm.
Now, through the “UP” and “DOWN” keys, it is possible scroll the colours.
1. Cold white
CW
2. Warm white
WW
Once positioned onto the desired colour, press “ENTER” to confirm. By the keys “UP”and “DOWN” select “ON” or
“OFF”. It is possible to activate or disactivate the colours. Press ENTER to confirm.
Now the unit is in FIXED COLOURS mode and the diplay will keep reading “COL”.
To exit from the FIXED COLOURS mode, press the “MENU” button, select “ACT” and press “ENTER” to confirm.
Select “OFF” to deactivate the FIXED COLOURS mode. Press ENTER to confirm.
8.3 SLAVE configuration
To set up the unit as SLAVE set the 5 channels DMX mode with address 001.
With this operation the working temperature of Leds can be checked.
Press the “MENU” button up to visualize “ADR”. Through the “UP” and “DOWN” keys select “TEM”. Press “ENTER”
to confirm.
The value of the operating temperature of LED, which should never be higher than 75°C, will appear. A higher
value indicates a malfunction of the fixture.
With this operation ALL the parameters can be set to the default values.
Press the “MENU” button up to visualize “ADR”. Through the “UP” and “DOWN” keys select “DEF”. Press “ENTER”
to confirm. Select “RES” or “CAN” to reset value or cancel operation.
Following parameters will be set to default values: dmx address, number of dmx channels, automatic mode, co-
lour mode.
An internal temperature sensor prevents the unit from overheating. The temperature sensor will limit the current
to leds, protecting their integrity, if the ambient temperature exceeds the one allowed.
To ensure maximum functionality and light output it is recommended to follow these instructions:
9.0 Led temperature
10.0 Default setting
11.0 Thermal protection
12.0 Maintenance
Attention!
Always remove mains power prior to opening up the fixture.