background image

English

25

1. Red

RED

2. Green

GRE

3. Blue

BLU

4. White

UHT

Once positioned onto the desired colour, press “ENTER” to confirm. By the keys “UP”and “DOWN” select “ON” or

“OFF”. It is possible to activate or disactivate the colours. Press ENTER to confirm. 

Now the unit is in FIXED COLOURS mode and the diplay will keep reading “COL”.

To exit from the FIXED COLOURS mode, press the “MENU” button, select “ACT” and press “ENTER” to confirm. 

Select “OFF” to deactivate the FIXED COLOURS mode. Press ENTER to confirm. 

8.2 DW MASTER configuration

The FIXED COLOURS mode ONLY works when 3 channels DMX mode is set.

To activate the FIXED COLOUR mode, press the “MENU” button up to visualize “ADR”. Through the “UP” and

“DOWN” keys select “COL”. Press “ENTER” to confirm.

Through the “UP” and “DOWN” keys select “ACT”. Through the “UP” and “DOWN” keys select “ON” or “OFF” to

activate or deactivate the FIXED COLOUR mode. Press “ENTER” to confirm.

Now, through the “UP” and “DOWN” keys, it is possible scroll the colours.

1. Cold white

CW

2. Warm white

WW

Once positioned onto the desired colour, press “ENTER” to confirm. By the keys “UP”and “DOWN” select “ON” or

“OFF”. It is possible to activate or disactivate the colours. Press ENTER to confirm. 

Now the unit is in FIXED COLOURS mode and the diplay will keep reading “COL”.

To exit from the FIXED COLOURS mode, press the “MENU” button, select “ACT” and press “ENTER” to confirm. 

Select “OFF” to deactivate the FIXED COLOURS mode. Press ENTER to confirm. 

8.3 SLAVE configuration

To set up the unit as SLAVE set the 5 channels DMX mode with address 001.

With this operation the working temperature of Leds can be checked.

Press the “MENU” button up to visualize “ADR”. Through the “UP” and “DOWN” keys select “TEM”. Press “ENTER”

to confirm.

The value of the operating temperature of LED, which should never be higher than 75°C, will appear. A higher

value indicates a malfunction of the fixture.

With this operation ALL the parameters can be set to the default values.

Press the “MENU” button up to visualize “ADR”. Through the “UP” and “DOWN” keys select “DEF”. Press “ENTER”

to confirm. Select “RES” or “CAN” to reset value or cancel operation.

Following parameters will be set to default values: dmx address, number of dmx channels, automatic mode, co-

lour mode.

An internal temperature sensor prevents the unit from overheating. The temperature sensor will limit the current

to leds, protecting their integrity, if the ambient temperature exceeds the one allowed.

To ensure maximum functionality and light output it is recommended to follow these instructions:

9.0 Led temperature

10.0 Default setting

11.0 Thermal protection

12.0 Maintenance

Attention! 

Always remove mains power prior to opening up the fixture.

Содержание EM437

Страница 1: ...EMERALD Manuale di istruzioni Instructions manual...

Страница 2: ...1 DMX functions with DMX MODE 4 channels 21 6 3 2 DMX functions with DMX MODE 5 channels 21 6 3 3 DMX functions with DMX MODE 6 channels 22 6 4 DMX functions DW 22 6 4 1 DMX functions with DMX MODE 2...

Страница 3: ...described in this manual 1 1 2 Installation Fix the unit with screws hooks or any other support able to bear the weight of the unit itself The unit installation actions must be performed by a qualifie...

Страница 4: ...0 Size 249mm 9 80 437mm 17 20 341mm 13 43 260mm 10 24 6 50mm 0 26 12 50mm 0 49 58mm 2 28 129 74mm 5 11 173 50mm 6 83 3 0 Packaging and transport Warning Griven S r l liability will cease upon consign...

Страница 5: ...position Use the holes 12 5 1 2 or 6 5 1 4 in the bracket to fix the unit 4 2 Adjusting light beam direction 1 Untighten the lateral screw 4 2 Rotate the bodies of the unit towards desired direction...

Страница 6: ...s are compatible with the unit features The unit must never be installed if not grounded electrically It is suggested to use a magnetothermic switch along the power supply line as prescribed by in for...

Страница 7: ...anel The display of the unit is programmed to turn off automatically after 20 seconds of non working To activate it just press UP DOWN UP DOWN keys When the display is actice the luminous intensity is...

Страница 8: ...rm 6 3 DMX functions RGBW 6 3 1 DMX functions with DMX MODE 4 channels 6 3 2 DMX functions with DMX MODE 5 channels 6 0 DMX function mode Warning In absence of DMX signal the led will remain OFF Chann...

Страница 9: ...In absence of DMX signal the led will remain ON Channel Function Value Description 1 Dynamic white 0 3 Warm white 100 Cold white 0 4 122 Warm white 100 Cold white from 0 to 100 123 132 Warm white 100...

Страница 10: ...AUT Press ENTER to confirm Through the UP and DOWN keys select ACT Through the UP and DOWN keys select ON or OFF to activate or deactivate the AUTOMATIC mode Press ENTER to confirm The projector will...

Страница 11: ...up as AUTOMATIC must be followed 7 4 SLAVE configuration RGBW To set up the unit as SLAVE set the DMX mode with address 001 7 5 SLAVE configuration DW To set up the unit as SLAVE set the 3 channels D...

Страница 12: ...ay will keep reading COL To exit from the FIXED COLOURS mode press the MENU button select ACT and press ENTER to confirm Select OFF to deactivate the FIXED COLOURS mode Press ENTER to confirm 8 3 SLAV...

Страница 13: ...e those components which have got deteriorated All components of the unit are available as spare parts at Griven dealers Exploded views wiring diagrams electronic layouts and advertising brochures are...

Страница 14: ...fficient connec tions Repair or replace damaged wires Unfinished data connection Insert a terminal plug in the output jack of the last unit of the connection Incorrect address assignment to the units...

Страница 15: ...Bulgaria 16 46042 CASTEL GOFFREDO MN Italy Telefono 0376 779483 Fax 0376 779682 0376 779552 http www griven com e mail griven griven com http www griven it e mail griven griven it User s manual rel 2...

Отзывы: