background image

G-SWA

Assembly and Operating Manual

7 Maintenance and care 

7.1 Disassembly of the SWA

(Behold Image 4)
1.

Disassemble the SWA.

2.

Loosen the Setscrew (pos. 6).

3.

Rotate the axis (pos.2) counter-clockwise until the flanges (pos.3) are released.

4.

Loosen the Setscrew (pos. 5).

5.

Remove the axis (pos. 2) from the upper assembly (pos. 1).

6.

Clean all parts thoroughly. Inspect for wear and defects.

7.

Lubricate all mating surfaces.

For assembly, reverse the order.

7.2 Torque specifications

M6 – 8,5 Nm; M8 – 20,6 Nm; M10 – 41 Nm; M12 – 71 Nm

8 Parts list

8.1 Spare and wear parts, depending on size

5

Quantity

 Description

 Upper assembly
 Axis
 Flange
 Screw nut

4
5

2

 Axis

 Setscrew

1
1
2
2
1

 Order-No.

 EG-SWA…-A

 Locking ring
 Lower assembly

7
7

 Index pin

1

Pos.  Description

2

3

Pos.

1

1
1

The SWA is virtually maintenance-free. Check the semi-cylindrical bolt in regular intervals for correct 

function. Keep the mating surface and the moving parts clean and lubricate them slightly.

Spare parts and component parts of the SWA can be found on our homepage:

www.grip-gmbh.com

6

Содержание G-SWA

Страница 1: ...h best regards Your GRIP GmbH GRIP GmbH Handhabungstechnik Alter Hellweg 70 Tel 49 231 96450 01 info grip gmbh com 44379 Dortmund Germany Fax 49 231 96450 50 www grip gmbh com SWA Connector 1 6 7 4 5 6 5 5 5 8 Warranty 7 2 Torque specification Parts list Assembly Maintenance and care 7 1 Disassembly Page 2 3 3 3 3 2 3 Environmental and operating conditions 2 4 Safety indication Scope of delivery T...

Страница 2: ...er clockwise till the stop This opens the flanges and releases the lower assembly The upper and lower assembly can now be pulled apart To assemble ensure the flanges are open when joining the upper and lower assembly Turn the allen key clockwise till stop to close the flanges Due to the wedge profile this locks the upper and lower assemblies together Be sure to use the predetemined tightening torq...

Страница 3: ...ceptions are units designed especially for the respective conditions Everyone who is responsible for assembly commissioning and maintenance must read and understand the complete operating instructions Improper use which affects the function und operational safety of the SWA Connector is prohibited In order to prevent damage to the connector as well as injuries to the operator the lower assembly or...

Страница 4: ...er the centering pin The angular orientation is determined by a fitting bore The lower assembly is mounted on grippers measuring instruments or other tools Again a centering should be generated If the SWA Connector can not be installed due to space limitations adapter flanges can be used Use screws according to DIN 912 ISO 4762 during mounting The screw in depth of the screws must be observed We r...

Страница 5: ...embly reverse the order 7 2 Torque specifications M6 8 5 Nm M8 20 6 Nm M10 41 Nm M12 71 Nm 8 Parts list 8 1 Spare and wear parts depending on size 5 Quantity Description Upper assembly Axis Flange Screw nut 4 5 2 Axis Setscrew 1 1 2 2 1 Order No EG SWA A Locking ring Lower assembly 7 7 Index pin 1 Pos Description 2 3 Pos 1 1 1 The SWA is virtually maintenance free Check the semi cylindrical bolt i...

Страница 6: ...G SWA Assembly and Operating Manual 9 Exploded view 6 Image 4 Image 5 Upper assembly Lower assembly ...

Страница 7: ...design Part 2 Technical principles ISO 12100 2 2003 Safety of Machinery Basic concepts general principles for design Part 1 Basic terminology and methodology ISO 12100 1 2003 In the case of reasoned requests the specific documents shall be sent to the national authorities as follows Post The product mentioned above may only be put into operation if it has been established applicable that the unit ...

Отзывы: