background image

G-SWA

Assembly and Operating Manual

2 Safety

2.1 Symbol

2.2 Intended use

2.3 Environmental and operating conditions

2.4 Safety indication

Dangers may arise from the unit, if:

the product is not installed or inserted properly,

the system is not used for its intended purpose,

the safety and installation notes are not observed. 

CAUTION! Never open the connector when the load is suspended!

3 Warranty

3

If the product is used as intended in 1-shift operation the warranty is valid for 24 months from the 

ex-works delivery date under observance the mandatory maintenance and lubrication intervals and 

the given operating conditions. Generally parts touching the work piece and wear parts are not 

part of the warranty. Wear parts are listed in chapter 8.1. The unit is considered to be defective if 

its basic function "Lock" is no longer functioning.

This symbol indicates possible hazards to persons or the SWA 

Connector.

Use this unit only in dry and splash-proof environments at room temperature as well as within the 

application parameters defined in the technical specifications. If this is not the case, warranty 

cannot be accepted. Exceptions are units designed especially for the respective conditions.

Everyone who is responsible for assembly, commissioning and maintenance must read and 

understand the complete operating instructions. Improper use, which affects the function und 

operational safety of the SWA Connector, is prohibited.

In order to prevent damage to the connector as well as injuries to the operator, the 

lower assembly or the tool must be secured by hand or other devices before opening 

the change system. Otherwise there is a risk that  irreparable damages to the tool or 

injury to the operator are caused by the unit falling down. 

NOTICE!

Conduct assembly, maintenance and repair work only outside the hazardous areas or 

when the power supply is switched off.

The SWA Connector has been designed as an interface between handling device and tool (e.g. gripper). 

Furthermore, the SWA can also be used in special solutions, automation and also as a general 

mechanical standard interface. The unit may only be used in the context of its technical specifications. 

The system is intended for the installation in a machine. The requirements of the applicable instructions 

must be considered and adhered to.

NOTICE! 

The unit may only be operated if the machine in which the unit is installed complies with the 

relevant provisions of the machinery directive 2006-42-EC.

Содержание G-SWA

Страница 1: ...h best regards Your GRIP GmbH GRIP GmbH Handhabungstechnik Alter Hellweg 70 Tel 49 231 96450 01 info grip gmbh com 44379 Dortmund Germany Fax 49 231 96450 50 www grip gmbh com SWA Connector 1 6 7 4 5 6 5 5 5 8 Warranty 7 2 Torque specification Parts list Assembly Maintenance and care 7 1 Disassembly Page 2 3 3 3 3 2 3 Environmental and operating conditions 2 4 Safety indication Scope of delivery T...

Страница 2: ...er clockwise till the stop This opens the flanges and releases the lower assembly The upper and lower assembly can now be pulled apart To assemble ensure the flanges are open when joining the upper and lower assembly Turn the allen key clockwise till stop to close the flanges Due to the wedge profile this locks the upper and lower assemblies together Be sure to use the predetemined tightening torq...

Страница 3: ...ceptions are units designed especially for the respective conditions Everyone who is responsible for assembly commissioning and maintenance must read and understand the complete operating instructions Improper use which affects the function und operational safety of the SWA Connector is prohibited In order to prevent damage to the connector as well as injuries to the operator the lower assembly or...

Страница 4: ...er the centering pin The angular orientation is determined by a fitting bore The lower assembly is mounted on grippers measuring instruments or other tools Again a centering should be generated If the SWA Connector can not be installed due to space limitations adapter flanges can be used Use screws according to DIN 912 ISO 4762 during mounting The screw in depth of the screws must be observed We r...

Страница 5: ...embly reverse the order 7 2 Torque specifications M6 8 5 Nm M8 20 6 Nm M10 41 Nm M12 71 Nm 8 Parts list 8 1 Spare and wear parts depending on size 5 Quantity Description Upper assembly Axis Flange Screw nut 4 5 2 Axis Setscrew 1 1 2 2 1 Order No EG SWA A Locking ring Lower assembly 7 7 Index pin 1 Pos Description 2 3 Pos 1 1 1 The SWA is virtually maintenance free Check the semi cylindrical bolt i...

Страница 6: ...G SWA Assembly and Operating Manual 9 Exploded view 6 Image 4 Image 5 Upper assembly Lower assembly ...

Страница 7: ...design Part 2 Technical principles ISO 12100 2 2003 Safety of Machinery Basic concepts general principles for design Part 1 Basic terminology and methodology ISO 12100 1 2003 In the case of reasoned requests the specific documents shall be sent to the national authorities as follows Post The product mentioned above may only be put into operation if it has been established applicable that the unit ...