![Grindex Minette Скачать руководство пользователя страница 4](http://html.mh-extra.com/html/grindex/minette/minette_installation-care-and-maintenance_2265335004.webp)
Installation, care and maintenance
Minette
4
Product description
Applications
Minette
is intended to be used for:
— pumping of water which may contain abrasive
particles.
The pumps are available in the following
versions: 1 - 3 phase.
Liquid temperature: standard version, max.
40°C (104°F).
Liquid density: max. 1100 kg/m
3
(9.2 lb per US
gal.).
The pumped liquid may contain particles up to
a size which corresponds to the openings in the
strainer. See drawing.
The pH of the pumped liquid: 5 – 8.
Depth of immersion: max. 20 m (65 ft).
For other applications contact your nearest
Grindex representative for information.
WARNING!
The pump may not be used
in an explosive or flammable
environment or for pumping
flammable liquids.
WARNING!
If the pump run dry or snore,
the pump surface and the sur-
rounding liquid may be hot.
Bear in mind the risk of burn
injuries.
WARNING!
The machine is not to be
installed in locations classified
as hazardous in accordance
with the national electric code,
ANSI/NFPA 70-1990
Voltage
V
Rated current
A
Starting current
A
220 D
8.1
44
230 D
8.1
47
380 Y
4.7
25
400 Y
4.7
27
415 Y
4.7
28
500 Y
3.7
21
550 Y
3.9
24
3~ 50 Hz, 2800 r/min
Rated output: 2.2 kW (3.0 hp)
Max cons.: 2,7 kW (3,6 hp)
Voltage
V
Rated current
A
Starting current
A
220 D
9.6
65
230 Y//
9.5
65
380 Y
5.6
37
460
Yser
4.7
32
480
Yser
4.9
34
575 Y
3.6
23
600 Y
3.6
24
3~ 60 Hz, 3410 r/min
Rated output: 2.6 kW (3.5 hp)
Max coons.: 3,1 kW (4,2 hp)
Motor data
Motor type: Squirrel-cage 1- or 3-phase in
-
duction motor for 50 Hz and 60 Hz markets.
Voltage
V
Rated current
A
Starting current
A
220
8.7
31
230
8.4
32
240
8.3
34
1~ 50 Hz, 2830 r/min
Rated output: 1.5 kW (2.0 hp)
Max cons.: 1,9 kW (2,5 hp)
Voltage
V
Rated current
A
Starting current
A
220
10.0
35
230
9.9
37
240
9.8
39
1~ 60 Hz, 3405 r/min
Rated output: 1.8 kW (2.4 hp)
Max cons.:2,2 kW (3,0 hp)