Installation, care and maintenance 

Minette

Visible parts on pump 

and installation

Pump casing and 

impeller

Condition of the oil

Oil quantity

Liquid in the inspec-

tion chamber

Recommended inspections:

Inspection of 

Action

WARNING!

If the seal leaks, the oil casing may be under pressure. 
Hold a rag over the oil casing screw in order to prevent 
splatter. See “Safety precautions” for additional informa-
tion.

WARNING!

If there has been leakage, the stator casing may be un-
der pressure. Hold a rag over the inspection screw to 
prevent splatter. See “Safety precautions” for additional 
information.

Lay the pump on its side.

Tilt the pump so that any liquid in the inspection chamber can run out 

through the hole.

If there is water in the stator casing, the cause may be:

— that the inspection screw is not sufficiently tight.

— that the O-ring on the inspection screw or its sealing surface is damaged.

— that an O-ring is damaged.

— that the cable entry is leaking.

If there is oil in the inspections chamber, the cause may be:

— that the inner mechanical seal is damaged. Contact a Grindex service  

  shop.

Replace or fix worn and damaged parts.

 

Make sure that all screws, bolts and nuts are tight.

Replace worn parts if they impair function.

A check of the condition of the oil can show whether there has been an 

increased leakage. Note! Air/oil mixture can be confused with water/oil 

mixture.

Insert a tube (or hose) into the oil hole. Cover the top end of the tube and 

take up a little oil from the bottom.

Change the oil if it contains too much water.  

See “Changing the oil”. Check again one week after changing the oil.

If the oil contains too much water again, the fault may be:

— that an oil screw is not sufficiently tight.

— that the O-ring on an oil screw or its sealing surface is damaged.

— that the mechanical seal is damaged. Contact a Grindex service shop.

0.31 litres (0.08 US gallon)

Содержание Minette

Страница 1: ...Installation care and maintenance MINETTE www grindex com No 89 73 79 Revision 02 2008 04 ...

Страница 2: ...e specification or design without notice Guarantee ___________________2 Data plate interpretation ________2 Safety precautions_____________3 Product description ____________4 Applications _____________________ 4 Motor data ______________________ 4 Dimensions and weights ____________ 5 Performance curves _________ 6 7 Transportation and storage ______8 Installation __________________8 Electrical co...

Страница 3: ...e that the machine or parts of the machine can not roll or fall over and injure people or dam age property 3 Make sure that the lifting equipment can han dle the weight you want to lift and that it is in good condition 4 Don t work under suspended load 5 Carry out the work on a sturdy workbench 6 Bear in mind the danger of electrical acci dents 7 Check that tools and other equipment are in good co...

Страница 4: ... Bear in mind the risk of burn injuries WARNING The machine is not to be installed in locations classified as hazardous in accordance with the national electric code ANSI NFPA 70 1990 Voltage V Rated current A Starting current A 220 D 8 1 44 230 D 8 1 47 380 Y 4 7 25 400 Y 4 7 27 415 Y 4 7 28 500 Y 3 7 21 550 Y 3 9 24 3 50 Hz 2800 r min Rated output 2 2 kW 3 0 hp Max cons 2 7 kW 3 6 hp Voltage V R...

Страница 5: ...5 Installation care and maintenance Minette Dimensions and weights ...

Страница 6: ... 1 phase 50 Hz Minette 3 phase 50 Hz 0 0 0 5 1 0 1 5 2 0 2 5 P1 hp kW 24 20 16 12 8 4 0 0 2 4 6 8 10 12 14 16 Capacity l s usgpm Head ft m 3 2 0 70 0 0 50 100 150 200 250 35 1 0 0 0 5 1 0 1 5 2 0 2 5 3 0 P1 hp kW 0 2 4 6 8 10 12 14 16 24 20 16 12 8 4 0 Capacity l s usgpm Head ft m 4 3 0 70 0 0 50 100 150 200 250 35 1 2 ...

Страница 7: ... 0 0 5 1 0 1 5 2 0 2 5 3 0 P1 hp kW 0 4 8 12 16 20 24 0 2 4 6 8 10 12 14 16 18 Capacity l s usgpm Head ft m 4 3 0 70 0 0 70 140 210 280 35 1 2 0 0 0 5 1 0 1 5 2 0 2 5 3 0 3 5 P1 hp kW 0 4 8 12 16 20 24 0 2 4 6 8 10 12 14 16 18 Capacity l s usgpm Head ft m 4 3 0 70 0 0 70 140 210 280 35 1 2 ...

Страница 8: ...re starting to work on the pump or moving the pump make sure that the pump is isolated from the power sup ply and cannot be energized This applies to the control cir cuit as well The pump is frostproof as long as it is operating or is immersed in the liquid If the pump is taken up when the temperature is below freezing the impeller may freeze The pump shall be operated for a short period after bei...

Страница 9: ...nd lead is cor rectly connected by testing it NOTE Make sure that the monitoring equipment incorporated in the product is correctly connected and in use WARNING If the pump is equipped with automatic level control or con tactor unit there is a risk of sudden restart WARNING Bear in mind the risk of elec trical shock if the electrical connections are not correctly carried out or if there is fault o...

Страница 10: ...n con struction sites and farms the earthed grounded socket must have an addi tional earth ground fault protection device GFI connected WARNING When pumping near a lake jetties beaches ponds fountains etc a safety dis tance of at least 20 m 65 ft between the person and the pump is applicable The pump must never be placed directly into a swim ming pool If used in connection with swimming pools spe ...

Страница 11: ...11 Installation care and maintenance Minette 50 60 Hz 3 SUBCAB SUBCAB AWG Screened cable with contactor unit Y or D with or without transformer operation ...

Страница 12: ...roved only for 250 V and below For other voltages when CSA approval is required a transformer is used to reduce the voltage over the thermal contacts As a consequence the transformer has to be disconnected when the connection is changed from 440 460 V Yser to 220 240 V Y or to 230 V single phase If the change is done from 220 240 V Y or 230 V single phase to 440 460 V Yser the transformer has to b...

Страница 13: ...ipped with SMART ROTASENSE rotation control Note the following at start Connect the pump to power If the pump fails to start and the fuses are correct shift two phases in the CEE plug or turn the knob on phase shifter to start the pump NOTE Do not reverse phase sequence while pump motor is running Doing so may cause temporary incorrect rotation resulting in damage to motor electronics and rotating...

Страница 14: ...have a major overhaul in a service shop once a year This requires special tools and should be done by an authorized service shop When the pump is new or when the seals have been replaced inspection is recommended after one week of operation WARNING Before starting to work on the pump or moving the pump make sure that the pump is isolated from the power sup ply and cannot be energized This applies ...

Страница 15: ...ring on the inspection screw or its sealing surface is damaged that an O ring is damaged that the cable entry is leaking If there is oil in the inspections chamber the cause may be that the inner mechanical seal is damaged Contact a Grindex service shop Replace or fix worn and damaged parts Make sure that all screws bolts and nuts are tight Replace worn parts if they impair function A check of the...

Страница 16: ...w position on the cable replace the seal sleeve check that the seal sleeve and the washers conform to the outside diameter of the cables Replace the cable if the outer jacket is damaged Make sure that the cable do not have any sharp bends and are not pinched If faulty contact an electrician Repair faults and notify supervisor of any faults or defects Contact a Grindex service shop Cables Starter e...

Страница 17: ...ill up with new oil A paraffin oil with viscosity close to ISO VG32 is recommended The pump is delivered from fac tory with this type of oil In applications where poisonous properties are of less concern a mineral oil with viscosity up to ISO VG32 can be used Always replace the O rings on the oil screws Put the screws back and tighten them Changing the oil Lift the pump horizontally on relief tabl...

Страница 18: ...a screw driver or similar L min 200 mm 7 9 inch see fig to prevent rotation of the impeller Loosen and remove the impeller screw and washer WARNING Worn impellers often have very sharp edges Use protec tive gloves Remove the strainer 1 phase impeller 3 phase impeller Remove the diffuser part ...

Страница 19: ...setting clearance Make sure that the end of the shaft is clean and free from burrs Polish off any flaws with fine emery cloth Grease end of shaft conical sleeve and the threads of the adjustment screw The proper lubrication is grease for bearings e g Exxon Mobile Unirex N3 or equivalent NOTE Remove surplus grease from conical and cy lindrical surfaces of the shaft and the sleeve thoroughly Align t...

Страница 20: ... torque 22 Nm 16 2 Lbf ft Lock the impeller with a screw driver or similar L min 200 mm 7 9 inch see fig to prevent rotation of the impeller Fit the washer and the greased impeller screw and tighten torque to 22 Nm 16 2 Lbf ft Check that the impeller rotates freely When changing an impeller or after service we recommend that the screw is first tightened to the prescribed torque and then turned an ...

Страница 21: ...ial tools exclusively for this pump type without which the servicing of the pump will be difficult and the pump can be very easily damaged Service log Most recent service date Pump No Hours of operation Remarks Sign Tools Part No Denomination Remarks 51 084 00 Spring puller Spring removal 410 164 Puller Main bearing 410 165 Puller Support bearing 410 166 Bearing mounting set Bearings ...

Страница 22: ...Installation care and maintenance Minette 22 Service log Most recent service date Pump No Hours of operation Remarks Sign ...

Страница 23: ...23 Installation care and maintenance Minette Service log Most recent service date Pump No Hours of operation Remarks Sign ...

Страница 24: ...Grindex AB Hantverkarvägen 24 Box 538 136 25 Haninge Sweden Tel 46 8 606 66 00 Fax 46 8 745 53 28 marketing grindex com www grindex com 897379 EN 2008 04 ...

Отзывы: