![Grill'D Violet Long Скачать руководство пользователя страница 10](http://html1.mh-extra.com/html/grilld/violet-long/violet-long_installation-and-operation-manual_2265069010.webp)
10
Possible cause:
•
Blockage in the chimney or flue channels of the heater.
•
The chimney height is not sufficient or the chimney is located next to a high obstacle.
•
There is cold air in the chimney; the chimney has not heated up.
•
Low quality or wet combustion material.
•
The chimney is installed incorrectly.
Troubleshooting methods:
•
Perform maintenance (paragraph 2.8).
•
Extend the chimney stack height.
•
Insulate the chimney stack with a non-combustible heat-insulation material.
•
Select a heat-insulated chimney stack.
•
Remove ash from the ash drawer.
•
Check combustion material for compliance with the requirements (paragraph 2.4).
•
Ensure supply of a sufficient volume of combustion air.
•
Check the correctness of chimney installation and/or compliance with the manufac-
turer’s requirements; trust the installation and disassembly of the chimney only to
qualified specialists.
3. INSTALLATION MANUAL
3.1. Before commencing installation of the heater
IMPORTANT! Make sure that all safety distances around the heater are observed. There
shall be no electrical appliances, cables, meltable and flammable materials within the
safety distances. Consider the safety distances from the chimney during installation!
•
The heater shall be installed in compliance with all local rules, including those referring to
European and national standards.
•
The chimney stack for the heater shall be individual, not joint combined for several appli-
ances.
•
For more information about fire safety requirements, please, address the local fire depart-
ment.
А
�
50-100
Естественная вентиляция
B
Естественная вентиляция
B
50
0
А
�
50-100
А
�
50-100
Естественная вентиляция
B
Естественная вентиляция
B
50
0
А
�
50-100
Figure 1.
Self-ventilation