The heater operation may be terminated after the entire load of firewood
burns up. To do so, wait for the complete cooldown of the heater, remove ash
from the firebox to the ash drawer, and then clean the ash box.
7)
Drain the water from the integrated tank.
IMPORTANT! It is prohibited to use salt solution to generate steam during
operation: pouring it onto the stone heater and the heater metal.
IMPORTANT! It is necessary to avoid ingress of water or salt solution onto
the exposed metal parts of the heater that are both in the heated and
unheated condition.
IMPORTANT! Partial burning out of heat-resistant enamel is possible on the
most thermally loaded elements of the heater during operation, which is
not a manufacturing defect.
IMPORTANT! The firebox metal may become slightly deformed during
operation, which is not a manufacturing defect provided the integrity of
weld joints is preserved.
IMPORTANT! In case there is a hot water tank, the water shall be drained
from the tank every time after termination of the heater operation, if the
temperature in the room drops below + 5 ⁰С during interruptions of the
heater operation.
9. SAFETY MEASURES
IMPORTANT! It is prohibited to touch hot surfaces of the heater, stones, and
chimney.
IMPORTANT! It is prohibited to dry clothes, items, objects, firewood, bath
brooms, etc., on the heater surface.
IMPORTANT! Combustible objects shall be spaced from the heater surface
not less than 500 mm.
IMPORTANT! It is prohibited to operate the heater with the door unclosed.
IMPORTANT! Do not stand too close to the heater when pour water onto
heated stones.
IMPORTANT! For safety reasons use gloves or special tools for opening the
door.
IMPORTANT! The heater shall be under supervision during the entire stoking
time. Do not entrust this responsible work to children.
10. TYPICAL FAULTS AND TROUBLESHOOTING METHODS
1) Fault:
Appearance of burning odor and (or) chemical odor.
Possible cause:
There is leftover industrial oil on the heater surface, and (or)
the odor comes from heat-resistant enamel.
Troubleshooting:
Stoke the heater in accordance with Section 7
2) Fault:
It takes a long time to heat the room.