Diamond LINQ Softener Single Tank Product Manual
pg. 7
3.
Setting up the tank:
A.
Fill the tank up to 30% full of water.
B.
Check the system specifications on page 2 to determine the correct amount of gravel and
resin needed for your system.
C.
Position the distributor tube so it is in the center of the tank,
shown in Figure 10.
D.
SLOWLY
, pour the correct amount of support gravel into the tank without getting any gravel
into the distributer tube.
E.
Visually confirm that the gravel is level and covering
the distributor basket and radials, if it is not, contact
Diamond H2O Conditioning.
F.
SLOWLY
, pour the correct amount of resin into the
tank. Try to keep the media level by carefully rocking
the tank back and forth.
G.
Fill the rest of the tank with water to prevent air from
getting in the tanks and potentially losing media.
H.
Verify that there is a large O-ring on the control
valve(s) adapter base. (Figure 12)
I.
Place the control valve on the tank, making sure that
the distributor tube fits into the bottom of the control
valve.
J.
Tighten the control valve onto the tank to the point
that it is snug. Double check that the valve is in a
correct position to be able to install the plumbing.
Figure 10: Centered Distributer Tube
Distributer
Tube
Resin
Gravel
Distributer
Basket &
Radials
Figure 11: Resin Tank Diagram
Figure 12: Valve Underside
O-Ring
Содержание Diamond H2O LINQ DLS-120-100
Страница 12: ...Diamond LINQ Softener Single Tank Product Manual pg 11 8 Programming ...
Страница 13: ...Diamond LINQ Softener Single Tank Product Manual pg 12 ...
Страница 14: ...Diamond LINQ Softener Single Tank Product Manual pg 13 ...
Страница 19: ...Diamond LINQ Softener Single Tank Product Manual pg 18 10 Troubleshooting ...
Страница 20: ...Diamond LINQ Softener Single Tank Product Manual pg 19 10 Troubleshooting 2 ...
Страница 21: ...Diamond LINQ Softener Single Tank Product Manual pg 20 ...