Diamond LINQ Softener Single Tank Product Manual
pg. 9
5.
Connect the Valves to the Water Source
A.
Pipe or tube a line from the Control Valve Drain (Figure 15) to the drain.
B.
DO NOT
install a valve in this line
use a pipe smaller than the unit’s inlet or outlet
make a direct connection to the drain
o
Provide an air gap at least four times the diameter of the drain pipe to
conform to sanitation codes and be able to observe the drain flow.
use an excessive amount of elbows in the plumbing
C.
Turn off the main water supply and open nearest faucet to relieve pressure. Connect the
facility plumbing to the control valve inlet and outlet following all local codes.
Note
: Make sure all piping is free of thread chips and other foreign matter.
D.
Turn the bypass valve to the “bypass” position (shown below).
E.
Turn the main supply on to restore water service to the home.
F.
Open the nearest faucet to evacuate air and re pressurize plumbing lines.
G.
Check for leaks.
6.
Connect the power supply
A.
1. Connect the power cord and plug power supply into a 115 volt / 60 Hz receptacle.
Electronic Connections
P = Power Supply
B = Powered in Backwash Step Only
(Cycle #1)
S = Powered for Entire Regen. Cycle
Figure 16: Bypass Valve Positions
Figure 17: Power Supply
Содержание Diamond H2O LINQ DLS-120-100
Страница 12: ...Diamond LINQ Softener Single Tank Product Manual pg 11 8 Programming ...
Страница 13: ...Diamond LINQ Softener Single Tank Product Manual pg 12 ...
Страница 14: ...Diamond LINQ Softener Single Tank Product Manual pg 13 ...
Страница 19: ...Diamond LINQ Softener Single Tank Product Manual pg 18 10 Troubleshooting ...
Страница 20: ...Diamond LINQ Softener Single Tank Product Manual pg 19 10 Troubleshooting 2 ...
Страница 21: ...Diamond LINQ Softener Single Tank Product Manual pg 20 ...