7.
Start up the system for the first time.
A.
Add about three gallons of water to the brine tank.
B.
Double check that the tanks are filled with water.
a.
Manually put the control valve into regeneration (Hold the SET/CHANGE button or press
the “regen now” button in the Diamond Linq app)
b.
While the system is in backwash (cycle 1), slowly change the adjust the bypass valve to the
“service” position.
c.
A mixture of air and water will flow from the drain line.
d.
Once the tank is filled, only water will be coming out of the drain line. Put the system back
into bypass operation. Run each step of the regen cycle (Figure 7) for a few minutes each.
You can advance to the next step by holding the SET/CHANGE button.
C.
Program the Valve. Most of the settings were programed to Diamond H2O’s default values.
The rest of the site-specific settings should be set by an installer after the water quality (pH,
TDS, total hardness, and iron) have been determined. These settings can be changed with the
valve’s two buttons (page 11) or by using the Diamond LINQ app (page 14).
Figure 18: Valve Buttons
Содержание Diamond H2O LINQ DLS-120-100
Страница 12: ...Diamond LINQ Softener Single Tank Product Manual pg 11 8 Programming ...
Страница 13: ...Diamond LINQ Softener Single Tank Product Manual pg 12 ...
Страница 14: ...Diamond LINQ Softener Single Tank Product Manual pg 13 ...
Страница 19: ...Diamond LINQ Softener Single Tank Product Manual pg 18 10 Troubleshooting ...
Страница 20: ...Diamond LINQ Softener Single Tank Product Manual pg 19 10 Troubleshooting 2 ...
Страница 21: ...Diamond LINQ Softener Single Tank Product Manual pg 20 ...