Table 3. Common Specifications for SR-G Series Grid Tie Power Invert
Technical Data of SR-G Series Grid Tie Power Inverter
Maximum Input DC Voltage
30 V
60 V
90 V
Peak power Tracking Voltage
14 V - 28 V
26V - 54 V
50 V - 82 V
Operating DC Voltage Range
Peak Inverter Effeciency
10.8 V - 30 V
10.8 V - 30 V
22 V - 60 V
22 V - 60 V
45 V - 90 V
45 V - 90 V
Nominal Voltage/Range
230V/190V-260V
115V/90V-140V
Frequency Range
46Hz~65 Hz
46Hz~65 Hz
Output Waveform
Pure Sine Wave
Pure Sine Wave
Power Factor
>0.95
>0.95
23
er
MPPT Effeciency
99%
Over Current Protection
Yes
Over Temperature Protection
Yes
Reverse Polarity Protection
Yes
Anit-Island Protection
Yes
Stackable
Just for AC Output
Operating Temperature Range
-20℃~ 45℃
-40℃~ 65℃
Storage Tmeperature Range
①.
②.
③.
2. Running time function (record load cumulative working hours).
3. Backlight function.
4. Power down data save function (save the number of kWh, operation time).
5. Large screen LCD display (display voltage, current, active power, electric energy,
cumulative running time)
④
. LCD Displayer Function Selecting Buttons.
UP: Short press will display power, electric energy, current and voltage in
anti-sequence.
DOWN: Short press will display power, electric energy, current and voltage in
sequence.
BACK LIGHT: Short press will open or close backlight.
⑤.
AC Output Outlet.The inverter will be attached a AC cable when you buy it, one
terminal of this AC cables should be connected to the AC output outlet, and another
terminal should be connected to the outlet of the utiltiy grid.
⑥.
Fan Ventilation Opening. Don’t cover this opening when the inverter is working.
INPUT DATA(DC)
SR-XXX-G-L-X
SR-XXX-G-M-X
SR-XXX-G-H-X
OUTPUT DATA(AC)
SR-XXX-X-E
SR-XXX-X-U
CHARACTERISTIC DATA