11 Notes to the calibration services 

Calibration certificates - DKD-certificates - other certificates: 
If device should be certificated for its accuracy, it is the best solution to return it with the referring sensors to 
the manufacturer. (please state desired test values, e.g. 25°C) 

12 Specification 

Measuring range

 

-

50.0 ... 400.0 °C  or  -58.0 ... 752.0 °F

 

Accuracy 
   Display 

 

 

Add. Output signal

 

(at nom. temperature 25°C) 
±0.4% of meas. value. ±0.2°C 
± 0.2% FS 

Media 

Non corrosive gasses 

Sensor 

Pt1000

 

Meas. frequency 

1 per second 

Adjusting 

Digital offset and scale adjustment for humidity and temperature 

Min-/Max-value memory 

Min and max measured values are stored 

Output signals 

refer to type plate,  

   Scaling 

both freely scalable by entering display values for 4mA (resp. 0V) and 20mA (resp. 
1V/10V) output 

   Connection 

  For option AV01, AV10 

4 - 20 mA    (2-wire) 
0 - 1 (10) V    (3-wire)  

  Auxiliary energy:

  

   (supply voltage, each output)

 

4 - 20 mA:   Uv = 12 - 30 V DC  
0-1V:  

Uv = 12 - 30 V DC, max. 10mA  

0-10V:  

Uv = 18 - 30 V DC, max. 10mA 

 

  Perm. impedance   

 

4 - 20 mA:   RA(Ohm) < ( (Uv - 12V) / 0,02A ) 

 

example: for Uv = 18V:  RA < (18V - 12V) / 0.02A     =>   RA < 300 Ohm

 

  Permissible load 

 

0 - 1 (10) V: RL(Ohm) > 3000 Ohm 

 

Display 

approx. 10 mm high, 4-digit LCD-display 

Operating elements 

3 keys  

Ambient conditions  
   Nom. temperature 
   Operating temperature 
    
 
 
   Relative humidity 
   Storage temperature 

 

25°C 
Electronics: -25 ... 70 °C  

Please consider that the allowable range of the housing and electronics 
must not be exceeded, especially when using the probe at higher 
temperatures!

 

Electronics: 0 ... 95 %RH (not condensing) 
-25 ... 70 °C

 

Housing 

ABS (IP65, except sensor head) 

   Dimensions 

82 x 80 x 55 mm (without elbow-type plug and sensor tube) 
for Option 

“Kabel”: Sensor head Ø14mm*68mm, 1m teflon cable, high humidity sensor 

   Mounting 

Holes for wall mounting (in housing - accessible after cover has been removed). 

   Mounting distance 

50 x 70 mm, max. shaft diameter of mounting screws is 4 mm 

   Electrical connection 

Elbow-type plug conforming to DIN 43650 (IP65), 
max. wire cross section: 1.5 mm², wire/cable diameter from 4.5 to 7 mm 

EMC 

The device corresponds to the essential protection ratings established in the 
Regulations of the Council for the Approximation of Legislation for the member 
countries regarding electromagnetic compatibility (2004/108/EG).  
In accordance with EN 61326-1

 

: 2006, additional errors: <1 % FS. When connecting 

long leads adequate measures against voltage surges have to be taken. 

 
 

 

 