Safety instructions 

This device has been designed and tested in accordance to the safety regulations 
for electronic devices. However, its trouble-free operation and reliability cannot be 
guaranteed unless standard safety measures and special safety advises given in 
this manual will be adhered to when using it. 

1.  Trouble-free operation and reliability of the device can only be guaranteed if it 

is not subjected to any other climatic conditions than those stated under 
“Specification”. 

2.  Transporting the device from a cold to a warm environment condensation may 

result in a failure of the function. In such a case make sure the device 
temperature has adjusted to the ambient temp. before trying a new start-up. 

3.  The circuitry has to be designed most carefully if the device should be 

connected to other devices. Internal connection in third party devices (e.g. 
connection GND and earth) may result in not-permissible voltages impairing or 
destroying the device or another device connected. 

4.  Whenever there may be a risk whatsoever involved in running it, the device 

has to be switched off immediately and to be marked accordingly to avoid re-
starting. Operator safety may be a risk if: 
- there is visible damage to the device or the device is not working as specified. 
- the device has been stored under unsuitable conditions for a longer time. 
In case of doubt, please return device to manufacturer for repair or 
maintenance. 

5. 

Warning: 

Do not use this product as safety or emergency stop device or in 

other applications where failure of the product could result in personal injury or 
material damage. Failure to comply with these instructions could result in death 
or serious injury and material damage. 

6.  This device only serves as supervision by the monitoring of essential or other 

for the customer important systems. 
It must not be used instead of compulsory approval monitoring devices and it is 
not designed for that purpose. If this device is used for the monitoring of such 
systems on its own, the manufacturer will not assume liability for damages 
whatsoever. 

7. 

Caution, acid!

 The sensor contains KOH. This can cause severe chemical 

burns.  If leaking, avoid contact! 

If there was contact:

 

- to skin: Flush contacted area with large amounts of water 
for several minutes. 
- to clothing: remove contaminated clothing. 
- to eyes: Flush with large amounts of water for several 
  minutes, obtain medical treatment. 

After swallowing:

 

- give large volumes of water. DO NOT induce vomiting! 
- Obtain medical treatment. 

 

 

Содержание GOX 100T

Страница 1: ...k GmbH Standort Greisinger Hans Sachs Stra e 26 D 93128 Regenstauf 49 0 9402 9383 0 49 0 9402 9383 33 info greisinger de Oxygen Measuring Device for diving gas mixtures WEEE Reg Nr DE 93889386 as of V...

Страница 2: ...s will be detected at calibration and the sensor element has to be replaced before the next measurement By means of the integrated hold function the MOD Display max operating depth and a specialized s...

Страница 3: ...y to avoid re starting Operator safety may be a risk if there is visible damage to the device or the device is not working as specified the device has been stored under unsuitable conditions for a lon...

Страница 4: ...has to be replaced measuring is valid On Off switch Press shortly change between actual value oxygen hold value oxygen hold value MOD in meters n or feet F Press shortly short display of the sensor ra...

Страница 5: ...out at other pressure conditions than the calibration The actual pressure has to be entered in the configuration for measurement and calibration The sensor s temperature dependency is compensated inte...

Страница 6: ...Press shortly the key the display shows for a short time i e 100 The rating is displayed in 10 percent steps 100 optimal sensor status Lower values are indicating that the sensor life time will soon b...

Страница 7: ...e 1 to 120 min OFF auto power off is deactivated continuous operation Abs air pressure factory setting 1013 mbar 500 1200 Input of absolute pressure of measured gas The absolute pressure is depending...

Страница 8: ...ed strain max 0 25 bar over under pressure Display approx 13 mm high 3 digit LCD Pushbuttons 3 keys for ON OFF min max value display calibration Nominal temp 25 C Ambient temp 0 to 45 C sensor 20 to 5...

Отзывы: