H72.0.01.6C-02
Operating Manual GMH 3431
page 14 of 14
_____________________________________________________
_____________________________________________________________________________
15 Reshipment and Disposal
15.1 Reshipment
All devices returned to the manufacturer have to be free of any residual of measuring media and
other hazardous substances. Measuring residuals at housing or sensor may be a risk for
persons or environment
Use an adequate transport package for reshipment, especially for fully functional devices.
Please make sure that the device is protected in the package by enough packing materials.
15.2 Disposal instructions
Batteries must not be disposed in the regular domestic waste but at the designated collecting
points.
The device must not be disposed in the unsorted municipal waste! Send the device directly to us
(sufficiently stamped), if it should be disposed. We will dispose the device appropriate and
environmentally sound.
16 Specification
Measuring
ranges
Anzahl
5
Conductivity 1 *) 0,0 ... 200,0 µS/cm
” 2 *) 0 ... 2000 µS/cm
” 3 *) 0,00 ... 20,00 mS/cm
” 4 *) 0,0 ... 200,0 mS/cm
Resistivity
0,005 ... 100,0 kOhm*cm
TDS
0,0 ... 1999 mg/l
Salinity
0,0 ... 70,0 g/kg (PSU)
Temperature
-5,0 ... +100,0 °C
23,0 ... 212,0 °F
Accuracy Conductivity ±0,5%
v.MW ±0,3 % FS bzw. ±2 µs/cm
Temperature ±0,2
K
Anschlüsse Conductivity,
Temperature
Permanently connected mesuring cell
Output
Serial interface (3.5mm jack) can be connected to USB or RS232 interface of a PC
via electrically isolated interface adapter USB3100, USB 3100 N, GRS3100 or
GRS3105 (see accessories).
Measuring cell
Two-electrode-conductivity-measuring cell with integrated temperature sensor
Electrode material special graphite
Schaftmaterial polysulfon
Abmessungen
dia. 12 mm, length 120 mm
Arbeitsumgebung -5 … +80°C (continous) bis +100°C (short-duration)
Display
4 digit 7-segment (main and secondary display) with additional symbols
Additional functions
Min / max / hold
Adjustment/Calibration
Cell correction manually or automatically via selectable reference solution
Housing
Break-proof ABS housing
Protection class
Front side IP65
Dimensions
L*W*H [mm]
142 x 71 x 26 mm
(L x W x H)
Working conditions
-25 to 50 °C; 0 to 95 % RH (non condensing)
Storage temperature
-25 bis 70 °C
Power supply
9V-battery, typ IEC 6F22 (included in scope of supply) or external
Current
consumption
2 mA (Out = Off)
Battery indicator Automatically if battery exhausted
and ’ bAt ’
Auto-Off-Funktion
Device will be automatically switched off if no key is pressed/no interface
communication takes place for the time of the power-off delay. The power-off delay
can be set to values between 1and 120 min.; it can be completely deactivated.
EMV
The device corresponds to the essential protection ratings established in the
Regulations of the Council for the Approximation of Legislation for the member
countries regarding electromagnetic compatibility (2004/108/EG). Additional fault:
<1%